The effects of preprimed oxygenators on gas transfer efficiency.

نویسندگان

  • Chen Gao
  • Alfred H Stammers
  • Rebecca L Ahlgren
  • Tunisia A Ellis
  • Hunter B Holcomb
  • Bernadette T Nutter
  • Ryan G Schmer
  • Lynette Hock
چکیده

Cancellation of on-pump coronary artery bypass grafting after the circuit is primed may result in the discarding of unused circuits. In some off-pump cases, a surgeon may request that the circuit be primed, but complete the surgical procedure without utilizing the circuit. The major concerns about the unused circuit are its sterility and the performance of the oxygenator after it has been primed for a long period of time. The goal of this study is to determine whether prepriming of the circuit with and without albumin has an effect on the gas transfer efficiency of oxygenators during simulated cardiopulmonary bypass. Monolyth integrated membrane lungs (Sorin Biomedical, Arvada, CO) were used to deoxygenate and oxygenate the bovine blood. Oxygenators were preprimed for 72 (N = 6) and 24 (N = 6) hours before testing. In control group (N = 6), oxygenators were tested immediately (0 h) after they were primed. Three different priming solutions were used: physiological saline solution (Group A); 1.25% of human albumin (Group B); and 5% human albumin (Group C). The blood was modified to the American Association of Medical Instrumentation Standards before testing. The blood flow through the oxygenators was set at 2 Lpm and 4 Lpm, with gas (FiO2 at 1.0) to blood flow ratio at 1:1. Cultures were also obtained from preprimed oxygenators to test circuit sterility. Oxygen transfer in oxygenators primed for 0 h at blood flow of 4 Lpm were 203 mL/min +/- 9.7 (Group A), 263.1 mL/min +/- 52.9 (Group B), and 270.5 mL/min +/- 13.1(Group C, p < .01 vs. Group A). In oxygenators preprimed for 72 h, the CO2 transfers were 135.0 mL/min +/- 21.8 (Group A), 104.9 mL/min +/- 2.4 (Group B), and 148.9 +/- 26.6 (Group C, p < .006 vs. Group B). In addition, the pressure drops were 56.5 mmHg +/- 5.5 (Group A), 82.6 mmHg +/- 13.4 (Group B), and 67.6 mmHg +/- 15.3 (Group C, p < .05 vs. Group B). In group A, O2 transfer were 203.5 mL/min +/- 9.7 (0 h), 272.4 mL/min +/- 66.6 (24 h), and 260.8 mL/min +/- 31.1 (72 h, p < .01 vs. 0 h). In group B, O2 transfer were 263.1 mL/min +/- 52.0 (0 h), 302.7 mL/min +/- 77.4 (24 h), and 235.2 mL/min +/- 16.5 (72 hr, p < .02 vs. 24 hr). Cultures obtained from 12 preprimed oxygenators presented no organism growth for up to 5 days. In conclusion, oxygen transfer increases in oxygenators preprimed with albumin immediately after they were primed. However, gas transfer decreased after they were primed with albumin for 72 h. Oxygenators preprimed for 24 h and 72 h with 0.9% saline had better O2 transfer than those primed for 0 h.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in vitro comparison of gas transfer and pressure drop of the Bentley Duraflo Coated Spiral Gold and the Medtronic Carmeda Coated Maxima hollow fiber membrane oxygenators.

Two models of heparin coated, hollow fiber membrane oxygenators were tested in vitro to compare gas transfer and transoxygenator pressure drop using an established protocol. Oxygen and carbon dioxide transfer rates were measured at blood flows of 2.5 and 5.0 liters per minute with gas flow: blood flow ratios of 1:1 and 2:1 at both blood flows. All testing was performed under normothermic condit...

متن کامل

Optimization of Heat Transfer Enhancement of a Domestic Gas Burner Based on Pareto Genetic Algorithm: Experimental and Numerical Approach

The present study attempts to improve heat transfer efficiency of a domestic gas burner by enhancing heat transfer from flue gases. Heat transfer can be augmented using the obstacles that are inserted into the flow field near the heated wall of the domestic gas burner. First, to achive the maximum efficiency, the insert geometry is optimized by the multi-objective genetic algorithm so that heat...

متن کامل

مدلسازی ریاضی و شبیه سازی تاثیر انتقال جرم و حرارت بر راندمان جداسازی ذرات جامد در شوینده‌های ونتوری

: In present study a mathematical model is developed in order to examine the effects of heat and mass transfer on removal efficiency of particulate matters in Venturi type scrubbers. The governing equations including the particulate concentration, gas temperature, droplets temperature, droplets diameter, and droplets velocity equations are obtained by using the conservation laws and solved nume...

متن کامل

A Simple One-Dimensional Model for Investigation of Heat and Mass Transfer Effects on Removal Efficiency of Particulate Matters in a Venturi Scrubber

In the present study a mathematical model is developed in order to examine the effects of heat and mass transfers on removal efficiency of particulate matters in venturi type <span style="font-size: 10...

متن کامل

Non-destructive evaluation of membrane lung gas exchange performance.

This paper describes a method of evaluating the gas exchange effectiveness of hollow fiber oxygenators utilizing gas on both sides of the membrane. The goal of the study was to develop an evaluation technique which was accurate, reliable, and did not harm or contaminate a new, sterile oxygenator. Three pediatric oxygenators were tested and compared: the Medtronic Minimax Plus, the Terumo Capiox...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2003