Dynamic morphology of the secundum atrial septal defect evaluated by three dimensional transoesophageal echocardiography.

نویسندگان

  • Y V Maeno
  • L N Benson
  • P R McLaughlin
  • C Boutin
چکیده

OBJECTIVE To define by three dimensional echocardiography the pattern and potential determinants of contraction of a secundum atrial septal defect through the cardiac cycle, and to evaluate the possibility of using cross sectional transthoracic and transoesophageal imaging to assess the dynamic nature of the defect. DESIGN Three dimensional echocardiography was performed using a multiplane transoesophageal probe on 50 patients with a secundum atrial septal defect (median age 9.8 years). Nine patients were excluded because of poor images or morphological features that precluded defect measurement. In 41 cases, defect area, long and short axis length, and distance of the attenuated anterior rim were measured in their largest and smallest dimensions. RESULTS Defect area changed significantly through the cardiac cycle (mean change 61%, p < 0.0001; range 17% to 86%). The defect contracted symmetrically and was not related to patient age, defect size, heart rate, Qp/Qs ratio, the presence of an aneurysmal atrial septum, or attenuated anterior rim. In all cases with an attenuated anterior rim (n = 13), the length of the rim significantly decreased (p = 0. 001) during atrial systole. Dynamic changes measured by either transthoracic or transoesophageal cross sectional images did not correlate with those obtained by three dimensional imaging. CONCLUSIONS Three dimensional echocardiography shows dynamic features of defects in the atrial septum. This information may lead to an improved understanding of the pathophysiology of atrial shunting.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of ostium secundum atrial septal defects by transoesophageal cross-sectional echocardiography.

Transoesophageal cross-sectional echocardiography has special advantages when investigating the interatrial septum which is imaged perpendicularly without echo dropouts from an oesophageal transducer position. The technique was successfully used in 19 out of 20 patients (95%) with an ostium secundum atrial septal defect and in 30 control subjects. In all of the latter the interatrial septum was...

متن کامل

Assessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography.

OBJECTIVE To apply three dimensional echocardiography to describe the geometric profile of the Amplatzer and Cardioseal occluders after deployment for closure of atrial septal defect. METHODS 20 patients (mean (SD) age, 14 (5) years) were enrolled for transcatheter closure of a secundum atrial septal defect with the Amplatzer occluder (10) or with the Cardioseal occluder (10). The two populat...

متن کامل

Assessing ASDs prior to device closure using 3D echocardiography. Just pretty pictures or a useful clinical tool?

AIMS To determine the usefulness of three-dimensional transthoracic echocardiography (3D echo) in assessment of secundum atrial septal defects (ASDs) considered for device closure. To compare the findings from 3D echo with those from two-dimensional transoesophageal echocardiography (TOE) regarding dimensions, morphology and suitability for device closure. METHODS AND RESULTS Twenty-four pati...

متن کامل

Transcatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography.

AIMS To examine the feasibility of transcatheter closure of multiple atrial septal defects using two Amplatzer devices simultaneously and to describe the importance and the role of two- and three-dimensional transoesophageal echocardiography in the selection and closure of such defects. METHODS Twenty-two patients with more than one atrial septal defect underwent an attempt at transcatheter c...

متن کامل

A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect

OBJECTIVES Transcatheter closure of a secundum atrial septal defect (ASD II) has become an effective alternative for surgical treatment. In this study we evaluated the correlation between the two-dimensional transoesophageal echocardiographic (2D TEE) sizing of ASDs and the actual diameter of occluders in patients undergoing device closure. METHODS The records of 54 patients who underwent tra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Heart

دوره 83 6  شماره 

صفحات  -

تاریخ انتشار 2000