Evaluation of factors influencing arterial Doppler waveforms in an in vitro flow phantom
نویسندگان
چکیده
PURPOSE The aim of this study was to investigate factors that influence arterial Doppler waveforms in an in vitro phantom to provide a more accurate and comprehensive explanation of the Doppler signal. METHODS A flow model was created using a pulsatile artificial heart, rubber or polyethylene tubes, a water tank, and a glass tube. Spectral Doppler tracings were obtained in multiple combinations of compliance, resistance, and pulse rate. Peak systolic velocity, minimum diastolic velocity, resistive index (RI), pulsatility index, early systolic acceleration time, and acceleration index were measured. On the basis of these measurements, the influences of the variables on the Doppler waveforms were analyzed. RESULTS With increasing distal resistance, the RI increased in a relatively linear relationship. With increasing proximal resistance, the RI decreased. The pulsus tardus and parvus phenomenon was observed with a small acceleration index in the model with a higher grade of stenosis. An increase in the distal resistance masked the pulsus tardus and parvus phenomenon by increasing the acceleration index. Although this phenomenon occurred independently of compliance, changes in the compliance of proximal or distal tubes caused significant changes in the Doppler waveform. There was a reverse relationship between the RI and the pulse rate. CONCLUSION Resistance and compliance can alter the Doppler waveforms independently. The pulse rate is an extrinsic factor that also influences the RI. The compliance and distal resistance, as well as proximal resistance, influence the pulsus tardus and parvus phenomenon.
منابع مشابه
I-46: Obstetrical Doppler
Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملI-44: Color Doppler Imaging in Impotence
Sexual impotent is very common entity and define as inability to induce or maintaining penile erection during sexual intercourse. Studies reveals about 10% of men aged 40-70 years have complete, 17% have mild and 25% have moderate amount of erectile dysfunction. The sexual impotence has different etiology including psychogenic, neurogenic, arteriogenic and venogenic causes. Current studies reve...
متن کاملFactors influencing the renal arterial Doppler waveform: a simulation study using an electrical circuit model (secondary publication)
PURPOSE The goal of this study was to evaluate the effect of vascular compliance, resistance, and pulse rate on the resistive index (RI) by using an electrical circuit model to simulate renal blood flow. METHODS In order to analyze the renal arterial Doppler waveform, we modeled the renal blood-flow circuit with an equivalent simple electrical circuit containing resistance, inductance, and ca...
متن کاملبرآورد سرعت موج پالس با استفاده از پارامترهای شریانی استخراج شده از تصاویر فراصوتی کاروتید
Background & Objective : Several indices have been introduced to estimate arterial stiffness that based on changes in brachial blood pressure. But because of the error resulted by the substitution of brachial blood pressure instead of the other central arteries, such as carotid, it will be very important to present elastic parameter based on the mechanical models without any emphasis on brach...
متن کامل