A photochemical method for in vitro evaluation of fluid flow in human dentine.

نویسندگان

  • Nezar Boreak
  • Hiroshi Ishihata
  • Hidetoshi Shimauchi
چکیده

OBJECTIVE To evaluate the flow dynamics of dentine fluid using a chemiluminescence method in vitro. MATERIALS AND METHODS Horizontally sliced coronal dentine specimens with thicknesses of 1.4, 1.6, 1.8, and 2.0mm (n=10 each) were prepared from extracted human third molars. After cleaning with EDTA, a mounted specimen was clamped between 2 acrylic chambers attached to both the occlusal and pulpal sides. The occlusal chamber, which was closed with a glass coverslip, was filled with a chemiluminescent solution (0.02% luminol and 1% sodium hydroxide in water). A trigger solution of 1% hydrogen peroxide and 1% potassium ferricyanide was injected into the pulpal chamber at a constant pressure of 2.5 kPa, and allowed to immediately flow into the patent dentinal tubules. Four consecutive measurements (T1-T4) were performed on each sample by recording the emission of chemiluminescence with a photodetector. The relationship between the crossing time of the liquid through the slice and dentine thickness was examined. RESULTS An apparent time delay was detected between the starting points of the trigger solution run and photochemical emission at T1. Dt (Dt, s) values of each thickness group were 13.6 ± 4.25 for 1.4mm, 18.1 ± 2.38 for 1.6mm, 28.0 ± 2.46 for 1.8mm, and 39.2 ± 8.61 for 2.0mm, respectively. Dt significantly decreased as dentine became thinner towards the pulp chamber (P<0.001). CONCLUSIONS The velocity of fluid flow increased both with increasing dentine depth or reduction of remaining dentine thickness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of two lattice Boltzmann methods for fluid flow simulation in a stirred tank

In the present study, commonly used weakly compressible lattice Boltzmann method and Guo incompressible lattice Boltzmann method have been used to simulate fluid flow in a stirred tank. For this purpose a 3D Parallel code has been developed in the framework of the lattice Boltzmann method. This program has been used for simulation of flow at different geometries such as 2D channel fluid flow an...

متن کامل

Laser scanning confocal microscopy coupled with hydraulic permeability measurements for elucidating fluid flow across porous materials: application to human dentine.

Laser scanning confocal microscopy (LSCM) coupled to a constant volume flow-pressure measuring system is introduced as a new technique for the quantitative measurement of fluid flow across porous materials. Such processes are ubiquitous from the life sciences to materials science and the methodology herein could find widespread application. The methodology has been applied to the detection of f...

متن کامل

2D Computational Fluid Dynamic Modeling of Human Ventricle System Based on Fluid-Solid Interaction and Pulsatile Flow

Many diseases are related to cerebrospinal .uid (CSF) hydrodynamics. Therefore, understanding the hydrodynamics of CSF .ow and intracranial pressure is helpful for obtaining deeper knowledge of pathological processes and providing better treatments. Furthermore, engineering a reliable computational method is promising approach for fabricating in vitro models which is essential for inventing gen...

متن کامل

In Vitro Ability of a Novel Nanohydroxyapatite Oral Rinse to Occlude Dentine Tubules

Objectives. The aim of the study was to investigate the ability of a novel nanohydroxyapatite (nHA) desensitizing oral rinse to occlude dentine tubules compared to selected commercially available desensitizing oral rinses. Methods. 25 caries-free extracted molars were sectioned into 1 mm thick dentine discs. The dentine discs (n = 25) were etched with 6% citric acid for 2 minutes and rinsed wit...

متن کامل

Experimental Investigation of the Permeability and Inertial Effect on Fluid Flow through Homogeneous Porous Media

The value of the permeability in fluid flow through porous media is important for process investigation. In low Reynolds number, the classic Darcy’s law is suitable for simulation of fluid flow. In this paper, an experimental study for evaluation of preformed fiber permeability has been done. Also, the deviations from the classical Darcy law by experimental and numerical simulation of the N...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of oral biology

دوره 60 1  شماره 

صفحات  -

تاریخ انتشار 2015