Soil Resistivity Data Computations; Single and Two - Layer Soil Resistivity Structure and Its Implication on Earthing Design

نویسنده

  • M. Nassereddine
چکیده

Performing High Voltage (HV) tasks with a multi craft work force create a special set of safety circumstances. This paper aims to present vital information relating to when it is acceptable to use a single or a two-layer soil structure. Also it discusses the implication of the high voltage infrastructure on the earth grid and the safety of this implication under a single or a two-layer soil structure. A multiple case study is investigated to show the importance of using the right soil resistivity structure during the earthing system design. Keywords—Earth Grid, EPR, High Voltage, Soil Resistivity Structure, Step Voltage, Touch Voltage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soil Resistivity Cut off Value and Concrete Pole Deployments in HV Transmission Mains

The prologue of new High Voltage (HV) transmission mains into the community necessitates earthing design to ensure safety compliance of the system. Concrete poles are widely used within HV transmission mains; many retired transmission mains with timber poles are being replaced with concrete ones, green transmission mains are deploying concrete poles. The earthing arrangement of the concrete pol...

متن کامل

Soil Resistivity Structure and Its Implication on the Pole Grid Resistance for Transmission Lines

High Voltage (HV) transmission lines are widely spread around residential places. They take all forms of shapes: concrete, steel, and timber poles. Earth grid always form part of the HV transmission structure, whereat soil resistivity value is one of the main inputs when it comes to determining the earth grid requirements. In this paper, the soil structure and its implication on the electrode r...

متن کامل

Design of Earthing System for a Substation : A Case Study

This paper presents the design of earthing system for 132 KV substation and simulation for calculation of required parameters. This paper is to provide information pertinent to safe earthing practices in ac substation design and to establish the safe limits of potential difference under normal and fault conditions. The grounding grid system of a practical 220 kV substation is calculated by MATL...

متن کامل

Determination of Soil Moisture Content at Bukit Bunuh Meteorite Impacted Area using Resistivity Method and Laboratory Test

Determination of soil moisture content is of vital importance to many fields of study; civil engineering, hydrology, agriculture, geology, ecology and forestry. The occurrence of impact crater in Bukit Bunuh, a meteorite impacted area, made it an area of great interest to many researchers. In view of the process of impact cratering, the subsurface soil characteristics such as moisture content o...

متن کامل

Earthing Techniques

1.3 MAKING A MEASUREMENT ........................................................................................................................................... 1.3.1 PRINCIPLES...............................................................................................................................................................4 1.3.2 SOIL RESISTIVITY TESTING PROCEDURE GUIDELINES ......

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013