New technique for determining cardiac output with use of a miniature esophageal scintillation detector.
نویسندگان
چکیده
A miniature scintillation detector recently designed and constructed in this laboratory can be inserted into the esophagus and under fluoroscopic vision positioned so that radioactivity emitted from the blood in the descending aorta can be detected and a time-concentration curve recorded from which cardiac output can be determined. Twenty simultaneous determinations of cardiac output by the isotope-dilution method with the esophageal scintillation counter probe and the dye-dilution technique were done in 10 dogs. There was a good correlation between the two methods. Among the technical advantages of the isotope-dilution method over the dye-dilution method are avoidance of arterial puncture, only one sample of venous blood required, an easily performed procedure, and ability to permit repeated determinations of cardiac output with a minimum of manipulation and trauma.
منابع مشابه
A New Technic for the Detection of Left-to-right Cardiac Shunts by Use of an Esophageal Geiger-mueller Tube.
THE left-to-right shunts found in small atrial or ventricular septal defects or in patent ductus arteriosus are easily demonstrated during cardiac catheterization by both rightand left-sided approaches.' Efforts to evaluate shunting due to these defects without cardiac catheterization have depended on measurements of the cardiac output curves obtained by various external counting technics.Y Bec...
متن کاملEvaluating the effects of esophageal and breast cancer radiotherapy on the cardiac function and determining the relationship between the dosimetric parameters and ejection fraction changes
Background: In the radiotherapy of patients with esophagus and breast cancer, the heart receives a significant dose of radiation that might cause heart complications. Thefore, the aim of the current study was to evaluate the effects of esophagus and left breast cancer radiotherapy on the cardiac function and to determine the relationship between the dosimetric parameters and ejection fraction (...
متن کاملAssessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
متن کاملA New Technic for the Detection of Left-to-Right Cardiac Shunts by Use
THE left-to-right shunts found in small atrial or ventricular septal defects or in patent ductus arteriosus are easily demonstrated during cardiac catheterization by both rightand left-sided approaches.' Efforts to evaluate shunting due to these defects without cardiac catheterization have depended on measurements of the cardiac output curves obtained by various external counting technics.Y Bec...
متن کاملNew approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...