Late driveline left ventricular assist device infection treated with frozen-and-thawed allogeneic platelet gel.

نویسندگان

  • Francesco Formica
  • Paolo Perseghin
  • Antonio Cirò
  • Giovanni Paolini
چکیده

In this case report, we report the application of frozen-and-thawed allogeneic platelet gel (PLT-gel) to treat a late driveline exit site infection in a 56-year old patient supported by a Heartware-HVAD left ventricular assist device. The treatment duration was 4 weeks and at the follow-up the skin around the exit site was free from further infection. PLT-gel can be used to treat local infection of the driveline exit site and to prevent further high-risk infections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left ventricular assist device driveline infection and the frequency of dressing change in hospitalized patients.

OBJECTIVES To determine if driveline infection is related to dressing change frequency in hospitalized adult patients with newly implanted left ventricular assist devices (LVAD). BACKGROUND Guidelines do not exist for the frequency of driveline exit-site dressing change in hospitalized patients resulting in wide variation in practice. METHODS A retrospective chart review was conducted on 68...

متن کامل

VeraFlo Negative Pressure Wound Therapy with Household Bleach for Refractory Driveline Infection in a Patient with Left Ventricular Assist Device

Driveline infections and sepsis are amongst the most common causes of morbidity and mortality in a patient with a left ventricular assist device. In this case, we present a patient with a multi drug resistant pseudomonas aeruginosa driveline exit site infection. Initially, it was treated with dual antibiotics, followed by surgical debridement utilizing Dakin’s solution irrigation and standard n...

متن کامل

The Jarvik 2000 is associated with less infections than the HeartMate left ventricular assist device.

OBJECTIVES Device-related infections remain a considerable problem of left-ventricular support. We compared the device-related-infections between the HeartMate left ventricular assist device (LVAD) and the Jarvik 2000 permanent LVAD, a device with a novel retroauricular power-supply. METHODS Between December 2000 and September 2002 we implanted the HeartMate-vented, electrical-system in 11 pa...

متن کامل

Heartmate II outflow graft ligation and driveline excision without pump removal for left ventricular recovery.

We report interruption of left ventricular assist device (VAD) support by way of outflow graft ligation and driveline excision while leaving the pump in situ. In this case, the indication for mechanical assist device separation was myocardial recovery, which occurred following 9 months of support. This case report demonstrates the feasibility of separating a patient from a VAD without the need ...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2014