Cardiac troponin I plasma levels for diagnosis and quantitation of perioperative myocardial damage in patients undergoing coronary artery bypass surgery.

نویسندگان

  • S Chocron
  • J P Etievent
چکیده

OBJECTIVE The definition of a reliable and generally accepted diagnostic standard for perioperative myocardial damage is desirable. Cardiac troponin I (cTnI) is highly specific for myocardial tissue and can be measured rapidly. The aim of our study was to evaluate the diagnostic potential of cTnI for myocardial lesions in patients undergoing coronary artery bypass surgery (CABG). METHODS A total of 119 patients with diffuse coronary artery disease were operated on using blood cardioplegia. Serial blood samples drawn before and after surgery were analyzed for the activity of creatine kinase MB isoenzyme (CKMB) and the concentrations of CKMB mass, cardiac troponins T and I. On the basis of the biochemical results (except cTnI) and the findings of electrocardiography/echocardiography, patients were classified and cTnI was studied for each group separately: group I, minor myocardial damage; group II, non-transmural infarction; group III, transmural infarction; and group IV, preoperative non-transmural infarction. RESULTS In 87 patients of group I (73.1%) cTnI levels remained low; 19 patients (16.0%) were assigned to group II, 8 patients (6.7%) to group III, and 5 patients (4.2%) to group IV. For discrimination of patients without and with perioperative myocardial infarction (PMI) by one cTnI determination, the use of cutoff values of 6.5 ng/ml at 8 h, 9.8 ng/ml at 12 h, and 11.6 ng/ml at 24 h after aortic unclamping resulted in a diagnostic efficiency of 88, 94 and 98%). Especially, a cTnI value at 24 h had a sensitivity of 100% and a specificity of 97%. Cardiac troponin levels at 24 h were found to correlate closely with the well-recognized 2-48 h area-under-the-curve (P < 0.0001; R = 0.993), making serial determinations unnecessary. CONCLUSIONS cTnI qualifies as a marker for diagnosis of PMI and quantitation of the amount of myocardial damage, because of the availability of a quick diagnostic test with high specificity, the high diagnostic efficiency, and especially the sufficient information gained by a single determination 24 h after aortic unclamping.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plasma Levels of MicroRNA-499 Provide an Early Indication of Perioperative Myocardial Infarction in Coronary Artery Bypass Graft Patients

BACKGROUND Recent studies indicated that microRNAs (miRNAs, miRs) were important for many biological and pathological processes, and they might be potential biomarkers for cardiovascular diseases. The present study aims to determine the release patterns of miRNAs in cardiac surgery and to analyze the ability of miRs to provide early prediction of perioperative myocardial infarction (PMI) in pat...

متن کامل

Cardioprotective Effect of Extended Remote Ischemic Preconditioning in Patients Undergoing Coronary Artery Bypass Grafting: A Randomized Clinical Trial

Background: The cardioprotective effect of ischemic preconditioning has been known for many years. Since the temporary ischemia in the heart may cause lethal cardiac effects, the idea of creating ischemia in organs far from the heart such as limbs was raised as remote ischemic preconditioning (RIPC). We hypothesized that the extension of RIPC has more cardioprotective effect in patients undergo...

متن کامل

Plasma levels of growth differentiation factor-15 are associated with myocardial injury in patients undergoing off-pump coronary artery bypass grafting

Growth differentiation factor-15 (GDF-15) has recently emerged as a risk predictor in patients with cardiovascular diseases. We therefore aimed to investigate the role of GDF-15 in the occurrence of cardiac injury during off-pump coronary artery bypass grafting (OPCAB). 55 consecutive patients with coronary artery diseases were recruited in this prospective, observational study. All patients we...

متن کامل

[Cardiac troponin I in perioperative myocardial infarction after coronary artery bypass surgery].

BACKGROUND AND AIMS Myocardial infarction after coronary artery bypass grafting is a serious complication and one of the most common causes of perioperative morbidity and mortality. The present study was designed to determine the relevance of serum cardiac troponin I as a specific diagnostic marker for perioperative myocardial infarction. METHODS A cohort of 64 patients undergoing coronary ar...

متن کامل

Markers for perioperative myocardial ischemia: what both interventional cardiologists and cardiac surgeons need to know.

All novel markers of myocardial ischemia (ischemia-modified albumin, choline, unbound free fatty acids) lack cardiac specificity. Therefore, for the specific detection of myocardial ischemia selective blood sampling from an inserted coronary sinus catheter is needed, which limits the applicability of these markers in most clinical routine settings. In addition, the superiority of these novel ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 1998