Patient-specific reconstructed anatomies and computer simulations are fundamental for selecting medical device treatment: application to a new percutaneous pulmonary valve.

نویسندگان

  • Claudio Capelli
  • Andrew M Taylor
  • Francesco Migliavacca
  • Philipp Bonhoeffer
  • Silvia Schievano
چکیده

Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation site morphology, size and dynamics, only about 15 per cent of cases are suitable for current devices. In order to increase the number of patients who could benefit from minimally invasive procedures, a new valved stent graft for percutaneous implantation has been designed recently. In this study, patient-specific computational analyses have been applied to investigate the suitability of new device designs, using real data from 62 patients who had undergone surgical pulmonary valve replacement. Magnetic resonance images of these patients before surgery were elaborated using imaging post-processing software to reconstruct the three-dimensional volume of each patient's implantation site. Three stent designs were created and tested in these patient outflow tracts using finite-element simulations: stent graft SG1 resembles the first device tested in animals; stent graft SG2 is a custom device tailored for a specific patient morphology; and stent graft SG3 represents a hypothetical larger device. The three devices showed an implantation success rate of 37 per cent, 42 per cent and 63 per cent, respectively. Using patient-specific simulations, we have shown that a percutaneous approach with these new devices may be possible for many patients who are currently referred for surgery. Furthermore, when the new devices become available, the methodologies described may help clinicians in the decision-making process, by enabling virtual implantation prior to the actual procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Geometrical and stress analysis of factors associated with stent fracture after melody percutaneous pulmonary valve implantation.

BACKGROUND Patients treated with the Melody device (Medtronic) for percutaneous pulmonary valve implantation experience stent fractures in ≈25% of the cases. The aim of this study is to identify the risk factors associated with fracture using 3-dimensional (3D) analyses. METHODS AND RESULTS In situ 3D shape of the Melody stent was reconstructed from 42 patients using procedural biplane fluoro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Philosophical transactions. Series A, Mathematical, physical, and engineering sciences

دوره 368 1921  شماره 

صفحات  -

تاریخ انتشار 2010