Validation of a standardized normalization template for statistical parametric mapping analysis of 123I-FP-CIT images.

نویسندگان

  • Aurélie Kas
  • Pierre Payoux
  • Marie-Odile Habert
  • Zoulikha Malek
  • Yann Cointepas
  • Georges El Fakhri
  • Philippe Chaumet-Riffaud
  • Emmanuel Itti
  • Philippe Remy
چکیده

UNLABELLED (123)I-FP-CIT ((123)I-N-omega-fluoropropyl-2beta-carbomethoxy-3beta-(4-iodophenyl)nortropane) is a SPECT dopamine transporter (DAT) tracer that probes dopaminergic cell loss in Parkinson's disease (PD). Quantification of (123)I-FP-CIT images is performed at equilibrium using a ratio (BR) of specific (striatal) to nonspecific (occipital) uptake with values obtained from regions of interest drawn manually over these structures. Statistical parametric mapping (SPM) is a fully automated voxel-based statistical approach that has great potential in the context of DAT imaging. However, the accuracy of the spatial normalization provided by SPM has not been validated for (123)I-FP-CIT images. Our first aim was to create an (123)I-FP-CIT template that does not require the acquisition of patient-specific MRI and to validate the spatial normalization procedure. Next, we hypothesized that this customized template could be used by different SPECT centers without affecting the outcomes of imaging analyses. METHODS The spatial normalization to the customized template created with SPM (template A1) was validated using (123)I-FP-CIT images obtained from 6 subjects with essential tremor (ET) with normal DAT status and 6 PD patients. Variability in BR values due to the normalization was evaluated using striatal volume of interest (VOI). To determine whether different SPECT centers could use a unique (123)I-FP-CIT template, we generated 3 other (123)I-FP-CIT templates using different subjects and image-processing schemes. The interchangeability of these templates was assessed using (a) putamen BR values analyzed with the intraclass correlation coefficient (ICC) and the Bland-Altman graphical analysis, and (b) SPM analysis comparing the results of group comparisons-that is, ET versus PD, obtained after normalization to each of the 4 templates. RESULTS There was no significant difference between pre- and post-normalization striatal BR values in our study. The mean variability calculated with putamen VOI values after normalization to each template was <10%, with the lowest ICC of 98%. Intergroup analyses performed with VOI and SPM approaches provided similar results independently of the template used. CONCLUSION SPM normalization was accurate even in subjects with low striatal (123)I-FP-CIT uptake, making it a promising approach for automatic analysis of (123)I-FP-CIT images using a single customized template at different centers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Creation and validation of an I-123 FP-CIT template for statistical image analysis using high-resolution SPECT for parkinsonian patients

OBJECTIVE The aim of this study was to create a new template for the anatomical normalization of I-123 FP-CIT SPECT images of Japanese people to evaluate dopamine transporter binding. METHODS The subjects consisted of 16 normal control subjects (5 females and 11 males; mean age ± SD, 51.6 ± 9.5 years, ranging from 25 to 62 years) and 21 parkinsonian patients (7 females and 14 males; mean age ...

متن کامل

Validation of Optimum ROI Size for 123I-FP-CIT SPECT Imaging Using a 3D Mathematical Cylinder Phantom

Objective(s): The partial volume effect (PVE) of single-photon emission computed tomography (SPECT) on corpus striatum imaging is caused by the underestimation of specific binding ratio (SBR). A large ROI (region of interest) set using the Southampton method is independent of PVE for SBR. The present study aimed to determine the optimal ROI size with contrast and SBR for striatum images and val...

متن کامل

Autopsy validation of 123I-FP-CIT dopaminergic neuroimaging for the diagnosis of DLB

OBJECTIVE To conduct a validation study of 123I-N-fluoropropyl-2b-carbomethoxy-3b-(4-iodophenyl) nortropane (123I-FP-CIT) SPECT dopaminergic imaging in the clinical diagnosis of dementia with Lewy bodies (DLB) with autopsy as the gold standard. METHODS Patients >60 years of age with dementia who had undergone 123I-FP-CIT imaging in research studies and who had donated their brain tissue to th...

متن کامل

Feasibility of Computed Tomography-Guided Methods for Spatial Normalization of Dopamine Transporter Positron Emission Tomography Image

BACKGROUND Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normaliza...

متن کامل

Improvement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database

Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 48 9  شماره 

صفحات  -

تاریخ انتشار 2007