Overhauser Geomagnetic Sensor Based on the Dynamic Nuclear Polarization Effect for Magnetic Prospecting
نویسندگان
چکیده
Based on the dynamic nuclear polarization (DNP) effect, an alternative design of an Overhauser geomagnetic sensor is presented that enhances the proton polarization and increases the amplitude of the free induction decay (FID) signal. The short-pulse method is adopted to rotate the enhanced proton magnetization into the plane of precession to create an FID signal. To reduce the negative effect of the powerful electromagnetic interference, the design of the anti-interference of the pick-up coil is studied. Furthermore, the radio frequency polarization method based on the capacitive-loaded coaxial cavity is proposed to improve the quality factor of the resonant circuit. In addition, a special test instrument is designed that enables the simultaneous testing of the classical proton precession and the Overhauser sensor. Overall, comparison experiments with and without the free radical of the Overhauser sensors show that the DNP effect does effectively improve the amplitude and quality of the FID signal, and the magnetic sensitivity, resolution and range reach to 10 pT/Hz 1 / 2 @1 Hz, 0.0023 nT and 20-100 μ T, respectively.
منابع مشابه
Microtesla MRI with dynamic nuclear polarization.
Magnetic resonance imaging at microtesla fields is a promising imaging method that combines the pre-polarization technique and broadband signal reception by superconducting quantum interference device (SQUID) sensors to enable in vivo MRI at microtesla-range magnetic fields similar in strength to the Earth magnetic field. Despite significant advances in recent years, the potential of microtesla...
متن کاملDevelopment of a Low Field Overhauser-Enhanced Magnetic Resonance Imaging System
High image contrast in magnetic resonance imaging (MRI) can be achieved by hyperpolarizing the nuclei of interest. Dynamic nuclear polarization (DNP) is a method to create hyperpolarization where excited electron spins induce a larger nuclear spin polarization. Imaging material that has been hyperpolarized by DNP is also known as Overhauser-enhanced magnetic resonance imaging (OMRI). An imager ...
متن کاملNuclear effects in Kerr rotation-detected magnetic resonance of electrons in GaAs
Wehave studied nuclear effects on electron spins in lightly doped n-GaAs bulk and quantumwell samples using optically detected magnetic resonance, with the optical detection done via Kerr rotation. The magnetic resonance signal allowed us to measure the electron T ∗ 2 lifetimes and g-factors. We observed strong dynamic nuclear polarization, which was controllable via nuclear magnetic resonance ...
متن کاملQuantitation of a spin polarization-induced nuclear Overhauser effect (SPINOE) between a hyperpolarized 13C-labeled cell metabolite and water protons
The spin polarization-induced nuclear Overhauser effect (SPINOE) describes the enhancement of spin polarization of solvent nuclei by the hyperpolarized spins of a solute. In this communication we demonstrate that SPINOEs can be observed between [1,4-(13) C2 ]fumarate, hyperpolarized using the dissolution dynamic nuclear polarization technique, and solvent water protons. We derive a theoretical ...
متن کاملCarbon and proton Overhauser DNP from MD simulations and ab initio calculations: TEMPOL in acetone.
A computational analysis of the Overhauser effect is reported for the proton, methyl carbon, and carbonyl carbon nuclei of liquid acetone doped with the nitroxide radical TEMPOL. A practical methodology for calculating the dynamic nuclear polarization (DNP) coupling factors by accounting for both dipole-dipole and Fermi-contact interactions is presented. The contribution to the dipolar spectral...
متن کامل