Glaucoma and Corneal Decompensation Following Cosmetic Iris Prosthesis Implantation: A Case Report

نویسندگان

  • Laura Morales-Fernandez
  • Jose M. Martinez-de-la-Casa
  • Lara Borrego
  • Rubén Sanchez-Jean
  • Pedro Arriola-Villalobos
  • Federico Saenz-Frances
  • Enrique Santos
  • Sofía García-Saenz
  • Julian Garcia-Feijoo
چکیده

Purpose: This case report illustrates the difficult management of complications produced following the bilateral iris implant of the NewColorIris (NewColorIris, Kahn, and Medical Devices. Methods: We report the case of a 36-year-old man who was referred to our outpatient clinic because of bilateral glaucoma showing a poor response to medical treatment and anti-glaucoma surgery. The young man had received an iris implant (NewColorIris, Kahn, Medical Devices) in both eyes for cosmetic purposes 5 years earlier. Surprisingly, his clinical records revealed a strictly normal ophthalmologic examination (visual acuity (VA) was 20/20 in both eyes) following NewColorIris explantation. Subsequent to this the patient required new artificial iris implantation, 2 anti-glaucoma surgeries (trabeculectomy+Ex-press®shunt placement) and cataract surgery in both eyes, and DSAEK in the left eye. On presentation, his VA was 20/200 in both eyes, endothelial cell count was less than 1000 and he showed diffuse corneal edema, iris retraction, anterior synechiae, iris implant in the sulcus, multifocal IOL and an intraocular pressure of 40 mmHg in both eyes. Results: Poor pressure control was resolved through Ahmed valve placement in both eyes though his vision remains poor. Conclusions: This clinical case highlights the serious, poorly manageable, irreversible complications produced by the NewColorIris implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two cases of cosmetic iris implant explantation secondary to uveitis, glaucoma, and corneal decompensation.

Cosmetic alteration of the iris color has long intrigued individuals. This has been accomplished with cosmetic contact lenses and most recently with intraocular artificial iris implants. We report 2 cases of uveitis, glaucoma, and corneal decompensation in women who underwent bi la tera l s imultaneous implantation of a non–US Food and Drug Administration–approved cosmetic iris implant (NewColo...

متن کامل

Complications secondary to cosmetic artificial iris anterior chamber implants: a case report

BACKGROUND Artificial iris anterior chamber implants were originally developed for therapeutic purposes but have been used recently for the cosmetic alteration of eye colour. There is a growing body of evidence surrounding their associated risks. We report a case presenting with complications secondary to bilateral NewColorIris® implants, including the first report of pressure-induced stromal k...

متن کامل

Femtosecond laser-assisted cataract surgery in patients with phakic intraocular lenses and low endothelial cell counts: a case report

BACKGROUND Phakic intraocular lens (PIOL) implantation has been used to correct myopia and myopic astigmatism, although corneal decompensation can occur after implantation. Femtosecond laser-assisted cataract surgery (FLACS) has gained in popularity due to its lower postoperative astigmatism and endothelial loss. Herein, we report the use of FLACS in patients who previously received PIOL implan...

متن کامل

Glaucoma tube shunt implantation through the ciliary sulcus in pseudophakic eyes with high risk of corneal decompensation.

PURPOSE To summarize our clinical experience with implanting Baerveldt glaucoma tube shunts through the ciliary sulcus in eyes with a posterior chamber intraocular lens and shallow anterior chambers, corneal transplants, guttata or edema. PATIENTS AND METHODS A retrospective interventional nonrandomized noncomparative case series. Main outcome measure was postoperative corneal status. Seconda...

متن کامل

Intraocular lens implantation for patients with coloboma of the iris

The aim of this study was to analyze the techniques for intraocular lens (IOL) implantation in patients with coloboma of the iris. A retrospective cohort study was used to analyze the degree of iris coloboma and the characteristics of the crystalline lens in 56 patients with iris coloboma. The patients with a lesser degree of coloboma of the iris and an intact lens capsule were treated by iris ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016