Whole-procedural Radiological Accuracy for Delivering Multi-session Gamma Knife Radiosurgery With a Relocatable Frame System
نویسندگان
چکیده
A newly developed Gamma Knife relocatable eXtend frame system has enabled the delivery of multi-session Gamma Knife radiosurgery without the use of skull pin fixation frame system. In this study, we investigate and report for the first time the whole procedural radiological accuracy for administering such treatments. To quantify the radiological alignment, the commonly used Winston-Lutz test was modified and used to determine the device accuracy of the eXtend frame system. Patient setup uncertainties relative to the device were further measured for a series of treatment sessions (n = 58), and then incorporated with the Winston-Lutz test results from individual patient-specific eXtend frame systems. The whole-procedure mean 3D radiological setup uncertainty was determined to be 0.69 ± 0.73 mm (1δ) from all the cases analyzed, and the mean 90% confidence level margins were found to be 0.55, 0.78 and 0.72 mm along the x-, y-, and z-axis, respectively. Our results therefore demonstrated that sub-millimetric radiological accuracy is clinically achievable for multi-session Gamma Knife radiosurgery treatments and a 1 mm margin along the major axes is sufficient for planning multi-session Gamma Knife radiosurgery treatments.
منابع مشابه
Monte Carlo Evaluation of Gamma Knife Dose Profile in Real Brain Phantom
Introduction The Gamma Knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. Dose calculations required in the system are performed by GammaPlan code; in this code, brain tissue is considered uniform. In the present study, we evaluated the effect of Gamma Knife system on the obtained dose through simulating a real ...
متن کاملSU-E-T-398: Verification of Gamma Knife EXtend System Based Fractionated Treatment Planning Using EBT2 Film.
PURPOSE To present EBT2 film verification of treatment planning with the eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery. METHODS A human head shaped phantom simulated the verification process for fractionated Gamma Knife (GK) treatment. Phantom preparation for eXtend Frame based treatment planning involved creating a dental impression, ...
متن کاملNursing perspective of gamma knife of treatment
Gamma knife is a new noninvasive method for treatment of patient with brain tumors. ‎Another name of this procedure is steriotatic radiosurgery.‎‏ ‏This computerized advanced ‎technique was implicated by a team including neurosurgeon, neuroradialogist, oncologist, and ‎a nurse. This method is used for treatment of certain brain tumors and lesions. The benefits are ‎l...
متن کاملLong term effects of Gamma knife Radiosurgery for treatment of cerebral arteriovenous malformations
Abstract Background: The Gamma Knife Radiosurgery (GKR) is an established management option for Cerebral Ar-teriovenous Malformations (AVMS). Therapeutic benefits of radiosurgery for arteriovenous malformations are complete obliteration of nidus with minimal neurological deficit. Methods: Radiosurgery was performed between February 2003 and April 2010 at Kamraniye day clinic, Teh-ran, Iran, us...
متن کاملبررسی بقا بر اساس سیستم نمرهبندی GPA در مبتلایان به متاستازهای مغزی درمان شده با رادیوسرجری گامانایف
Abstract Background: This study was done to define the role of Graded Prognostic Assessment (GPA) score for predicting overall survival in patients diagnosed with brain metastases undergoing Gamma-knife radiosurgery. Materials and methods: Patients diagnosed with brain metastases who were candidates for Gamma-knife radiosurgery entered this cross sectional study between 2003 and 2011. Clin...
متن کامل