Cyanoacrylate tissue adhesives - effective securement technique for intravascular catheters: in vitro testing of safety and feasibility.
نویسندگان
چکیده
Partial or complete dislodgement of intravascular catheters remains a significant problem in hospitals despite current securement methods. Cyanoacrylate tissue adhesives (TA) are used to close skin wounds as an alternative to sutures. These adhesives have high mechanical strength and can remain in situ for several days. This study investigated in vitro use of TAs in securing intravascular catheters (IVC). We compared two adhesives for interaction with IVC material, comparing skin glues with current securement methods in terms of their ability to prevent IVC dislodgement and inhibit microbial growth. Two TAs (Dermabond, Ethicon Inc. and Histoacryl, B. Braun) and three removal agents (Remove™, paraffin and acetone) were tested for interaction with IVC material by use of tensile testing. TAs were also compared against two polyurethane (standard and bordered) dressings (Tegaderm™ 1624 and 1633, 3M Australia Pty Ltd) and an external stabilisation device (Statlock, Bard Medical, Covington) against control (unsecured IVCs) for ability to prevent pull-out of 16 G peripheral IVCs from newborn fresh porcine skin. Agar media containing pH-sensitive dye was used to assess antimicrobial properties of TAs and polyurethane dressings to inhibit growth of Staphylococcus aureus and Staphylococcus epidermidis. Neither TA weakened the IVCs (P >0.05). Of removal agents, only acetone was associated with a significant decrease in IVC strength (P <0.05). Both TAs and Statlock significantly increased the pull-out force (P <0.01). TA was quick and easy to apply to IVCs, with no irritation or skin damage noted on removal and no bacterial colony growth under either TA.
منابع مشابه
In-vitro evaluation of antibacterial potential of cyanoacrylate tissue adhesives for intraoral wound closure
Background: Cyanoacrylate tissue adhesives have been used as a substitute to silk for intraoral wound closure. Placement of sutures provides a corridor for accumulation of microorganisms into tissue which leads to infection. Cyanoacrylate-based adhesives exhibit many properties of an ideal wound closure agent, minimizing the problems generated by suturing thread. The antimicrobial properties of...
متن کاملNovel technologies can provide effective dressing and securement for peripheral arterial catheters: A pilot randomised controlled trial in the operating theatre and the intensive care unit.
BACKGROUND Peripheral arterial catheters are widely used in the care of intensive care patients for continuous blood pressure monitoring and blood sampling, yet failure - from dislodgement, accidental removal, and complications of phlebitis, pain, occlusion and infection - is common. While appropriate methods of dressing and securement are required to reduce these complications that cause failu...
متن کاملExtracorporeal membrane oxygenation line-associated complications: in vitro testing of cyanoacrylate tissue adhesive and securement devices to prevent infection and dislodgement
BACKGROUND Extracorporeal membrane oxygenation (ECMO) delivers cardiac and/or respiratory support to critically ill patients who have failed conventional medical therapies. If the large-bore cannulas used to deliver ECMO become infected or dislodged, the patient consequences can be catastrophic. ECMO cannula-related infection has been reported to be double the rate of other vascular devices (7....
متن کاملAntibacterial Modification of Intravascular Catheter Surface for the Prevention of Catheter-Associated Infection
Objective: Intravascular catheter-associated infection has been increasing hospitalization in post-surgery patients mainly due to microbial colonization of the catheter surface and formation of a superficial biofilm layer. The present study is aimed in developing an effective antibacterial device which can prevent colonization of organisms by modification of catheter. Methods: In the present st...
متن کاملAntibacterial Modification of Intravascular Catheter Surface for the Prevention of Catheter-Associated Infection
Objective: Intravascular catheter-associated infection has been increasing hospitalization in post-surgery patients mainly due to microbial colonization of the catheter surface and formation of a superficial biofilm layer. The present study is aimed in developing an effective antibacterial device which can prevent colonization of organisms by modification of catheter. Methods: In the present st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anaesthesia and intensive care
دوره 40 3 شماره
صفحات -
تاریخ انتشار 2012