Polarography: an oxygen survey correlating oxygen transmissibility to "EOP" values.
نویسندگان
چکیده
A polarographic oxygen electrode was used to measure the oxygen transmissibility of seven contact lenses of varying water content and center thickness. A similar electrode was used to measure the oxygen uptake following wear of these same contact lenses for both the open- and closed-eyelid conditions on five young healthy subjects. Linear regression revealed a strong correlation between oxygen transmissibility and equivalent oxygen percentage (EOP) values for both the open- and closed-eyelid conditions. This strong correlation between these two oxygen parameters shows both are useful in predicting the oxygen tensions across the tear-epithelial interface during contact lens wear.
منابع مشابه
Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses.
The relationship between corneal edema and hydrogel lens oxygen transmissibility was examined for both daily and extended contact lens wear by measuring the corneal swelling response induced by a variety of contact lenses over a 36-hr wearing period. The relationships derived enable average edema levels that occur with daily and extended wear in a population of normal young adults to be predict...
متن کاملDirect noninvasive measurement of tear oxygen tension beneath gas-permeable contact lenses in rabbits.
PURPOSE To develop a noninvasive measurement of tear oxygen tension and to determine tear oxygen tension and calculated oxygen flux rates during wear of contact lenses of varying oxygen transmissibility (Dk/L). METHODS The basis of the tear oxygen tension (PO2) measurement is phosphorescence quenching of Pd-meso-tetra-(4-carboxyphenyl) porphine by oxygen. A fiber-optic bundle, positioned appr...
متن کاملOxygenDissociationCurvesfor Whole Blood,Recordedwithan Instrument That ContinuouslyMeasuresPo2and S02Independentlyat Constantt, p, and pH
We describe a method for recording oxygen dissociation curves for whole-blood specimens. The blood sample is placed in a thermostated measuring chamber, and Po2 and S02 are measured continuously by polarography and by reflectometry, respectively. During the recording of an oxygen dissociation curve, the po2 and S02 signals are stored in a data-acquisition system, while pH, Pco2 and temperature ...
متن کاملCorrection for Li et al., Functional connectivity arises from a slow rhythmic mechanism.
The mechanism underlying temporal correlations among blood oxygen level-dependent signals is unclear. We used oxygen polarography to better characterize oxygen fluctuations and their correlation and to gain insight into the driving mechanism. The power spectrum of local oxygen fluctuations is inversely proportional to frequency raised to a power (1/f) raised to the beta, with an additional posi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 25 12 شماره
صفحات -
تاریخ انتشار 1984