Portable Fourier transform infrared spectroradiometer for field measurements of radiance and emissivity.

نویسندگان

  • A R Korb
  • P Dybwad
  • W Wadsworth
  • J W Salisbury
چکیده

A hand-held, battery-powered Fourier transform infrared spectroradiometer weighing 12.5 kg has been developed for the field measurement of spectral radiance from the Earth's surface and atmosphere in the 3-5-µm and 8-14-µm atmospheric windows, with a 6-cm(-1) spectral resolution. Other versions of this instrument measure spectral radiance between 0.4 and 20 µm, using different optical materials and detectors, with maximum spectral resolutions of 1 cm(-1). The instrument tested here has a measured noise-equivalent delta T of 0.01 °C, and it measures surface emissivities, in the field, with an accuracy of 0.02 or better in the 8-14-µm window (depending on atmospheric conditions), and within 0.04 in accessible regions of the 3-5-µm window. The unique, patented design of the interferometer has permitted operation in weather ranging from 0 to 45 °C and 0 to 100% relative humidity, and in vibration-intensive environments such as moving helicopters. The instrument has made field measurements of radiance and emissivity for 3 yr without loss of optical alignment. We describe the design of the instrument and discuss methods used to calibrate spectral radiance and calculate spectral emissivity from radiance measurements. Examples of emissivity spectra are shown for both the 3-5-µm and 8-14-µm atmospheric windows.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Emissivity and Reflection Model for Calculating Water Surface-leaving Infrared Radiance

Published emissivity models provide calculated emissivity spectra for a given set of optical constants, view angles and local wind speeds. While these models have gained widespread acceptance, discrepancies have been identified against field measurements obtained from IR Fourier transform spectrometers (FTS) at view angles ≥40°. We therefore have developed an alternative approach for calculatin...

متن کامل

Surface Emissivity Impact on Temperature and Moisture Soundings from Hyperspectral Infrared Radiance Measurements

An accurate land surface emissivity (LSE) is critical for the retrieval of atmospheric temperature and moisture profiles along with land surface temperature from hyperspectral infrared (IR) sounder radiances; it is also critical to assimilating IR radiances in numerical weather prediction models over land. To investigate the impact of different LSE datasets on Atmospheric Infrared Sounder (AIRS...

متن کامل

Infrared Measurements of Pristine and Disturbed Soils 2. Environmental Effects and Field Data Reduction

We have expanded on previous methods for correcting sense, the requirement of thermodynamic equilibrium in thermal infrared field measurements for atmospheric Kirchhoff ’s law is violated (Badenas, 1997). downwelling radiance (Salisbury and D’Aria, 1992; Korb Nerry et al. (1990a,b) and Labed and Stoll (1991) et al., 1996; Hook and Kahle, 1996) by comparing the used the ‘‘emissivity box’’ approa...

متن کامل

Methodologies and protocols for the collection of midwave and longwave infrared emissivity spectra using a portable field spectrometer

The development of highly portable field devices for measuring midwave and longwave infrared emissivity spectra has greatly enhanced the ability of scientists to develop and verify exploitation algorithms designed to operate in these spectral regions. These data, however, need to be collected properly in order to prove useful once the scientists return from the field. Attention to the removal o...

متن کامل

Comparison of field and laboratory collected midwave and longwave infrared emissivity spectra / data reduction techniques

Many targets that remote sensing scientists encounter when conducting their research experiments do not lend themselves to laboratory measurement of their surface optical properties. Removal of these targets from the field can change their biotic condition, disturb the surface composition, and change the moisture content of the sample. These parameters, as well as numerous others, have a marked...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 35 10  شماره 

صفحات  -

تاریخ انتشار 1996