Effects of polarity for monophasic and biphasic shocks on defibrillation efficacy with an endocardial system.

نویسندگان

  • M Usui
  • G P Walcott
  • S A Strickberger
  • D L Rollins
  • W M Smith
  • R E Ideker
چکیده

Electrode polarity has been reported to be one of the factors that affect defibrillation efficacy. We studied the influence of polarity on defibrillation efficacy when monophasic and biphasic waveforms were used with an endocardial lead system. In six anesthetized pigs, defibrillation catheters were placed in the right ventricular (RV) apex and at the junction of the superior vena cava (SVC) and right atrium. Monophasic shocks were 6 ms in duration, while for biphasic shocks the first phase was 6 ms and the second was 4 ms in duration. Four electrode configurations were tested: R:S, M (the RV electrode, cathode; the SVC electrode, anode, with a monophasic shock); S:R: S, B(the RV electrode, first phase cathode; the SVC electrode, first phase anode, with a biphasic shock); S:R, B. Defibrillation probability of success curves were determined using an up/down protocol requiring 15 shocks for each configuration. For monophasic shocks, total delivered energy at the 50% probability of success point was significantly lower when the RV electrode was an anode than when it was a cathode (R: S, M: 24.4 +/- 7.4 J [mean +/- SD] vs S:R, M: 16.4 +/- 5.5 J; P < 0.05). For biphasic shocks, total energy was not affected by polarity reversal of the electrodes (R:S, B: 8.7 +/- 1.4 J vs S:R, B: 8.4 +/- 2.5 J; P = NS). The endocardial electrode configuration with the RV electrode as an anode requires less energy for defibrillation with a monophasic but not a biphasic waveform.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of a novel rectilinear biphasic waveform with a damped sine wave monophasic waveform for transthoracic ventricular defibrillation. ZOLL Investigators.

OBJECTIVES We compared the efficacy of a novel rectilinear biphasic waveform, consisting of a constant current first phase, with a damped sine wave monophasic waveform during transthoracic defibrillation. BACKGROUND Multiple studies have shown that for endocardial defibrillation, biphasic waveforms have a greater efficacy than monophasic waveforms. More recently, a 130-J truncated exponential...

متن کامل

Relation of atrial refractoriness to upper and lower limits of vulnerability for atrial fibrillation/flutter following implantable ventricular defibrillator shocks.

BACKGROUND Implantable ventricular cardioverter defibrillator (ICD) shocks can cause atrial fibrillation/flutter (AF). This study investigated the pathogenesis of AF after ICD shocks in a canine model. METHODS AND RESULTS The study was conducted in 8 dogs. In 5 dogs (group 1), truncated exponential (8 ms, 78% tilt) monophasic and biphasic shocks were delivered through a bipolar epicardial (pa...

متن کامل

Disparate effects of biphasic and monophasic shocks on postshock refractory period dispersion.

The magnitude by which a defibrillation shock extends the refractory period immediately postshock (refractory period extension, RPE) does not explain why biphasic shocks defibrillate with greater efficacy than monophasic shocks. It may be that spatial heterogeneity of RPE is a more important regulator of defibrillation efficacy. We measured RPE in 15 pentobarbital-anesthetized swine using 400-V...

متن کامل

Epicardial mapping of ventricular defibrillation with monophasic and biphasic shocks in dogs.

To study the mechanism of defibrillation and the reason for the increased defibrillation efficacy of biphasic waveforms, the potential gradient in a 32 x 30-mm region of the right ventricle in 15 dogs was progressively lowered in four steps while a strong potential gradient field was maintained throughout the rest of the ventricular myocardium. The volume of right ventricle beneath the plaque w...

متن کامل

The effects of biphasic and conventional monophasic defibrillation on postresuscitation myocardial function.

OBJECTIVES The purpose of this study was to compare the effects of biphasic defibrillation waveforms and conventional monophasic defibrillation waveforms on the success of initial defibrillation, postresuscitation myocardial function and duration of survival after prolonged ventricular fibrillation (VF). BACKGROUND We have recently demonstrated that the severity of postresuscitation myocardia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 1996