Transcranial Doppler ultrasonographic changes after treatment for arteriovenous malformations.

نویسندگان

  • G W Petty
  • A R Massaro
  • T K Tatemichi
  • J P Mohr
  • S K Hilal
  • B M Stein
  • R A Solomon
  • D I Duterte
  • R L Sacco
چکیده

We performed transcranial Doppler ultrasonography on 15 patients with arteriovenous malformations before and after embolization or surgical resection to compare quantitatively the hemodynamic effects of these two treatments. Changes in mean blood velocity and pulsatility index were analyzed in 19 treated feeding arteries. Blood velocity decreased by a mean of 38.1% or 46.5 cm/sec (p less than 0.0001, two-tailed paired t test); decreases were greater for surgically resected arteries (46.2% or 55.9 cm/sec, p less than 0.003) than for embolized arteries (30.8% or 38.0 cm/sec, p less than 0.0003). Pulsatility index increased by a mean of 54.7% or 0.25 (p = 0.0001); increases were greater for surgically resected arteries (65.8% or 0.29, p = 0.0045) than for embolized arteries (44.8% or 0.20, p less than 0.001). The differences in the changes in blood velocity and pulsatility index between treatment groups were not significant. These data demonstrate that embolization results in hemodynamic changes that are qualitatively similar to those occurring after surgical resection of arteriovenous malformations. Transcranial Doppler ultrasonography is a reliable and convenient noninvasive method for monitoring hemodynamic effects of treatments for arteriovenous malformations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Grading and hemodynamic follow-up study of arteriovenous malformations with transcranial Doppler ultrasonography.

This study presents and tests the clinical validity of a hemodynamic grading system that depends on noninvasive transcranial Doppler ultrasonographic parameters. The suggested transcranial Doppler-based grading system was compared with the Spetzler-Martin anatomic grading for prognosticative validity and clinical dependability. We concluded the following: (1) The pulsatility index was shown to ...

متن کامل

Transcranial Doppler of a paradoxical brain embolism associated with a pulmonary arteriovenous fistula.

We herein report the case of a patient who had paradoxical brain embolism owing to a pulmonary arteriovenous fistula (PAVF) who was diagnosed as having a right-to-left shunt by transcranial Doppler (TCD) with saline contrast medium. TCD with saline contrast medium failed to detect any high-intensity transient signals immediately after catheter embolization of the PAVF. Thus, TCD with saline con...

متن کامل

Relationship of transcranial Doppler flow velocities and arteriovenous malformation feeding artery pressures.

BACKGROUND AND PURPOSE Feeding mean arterial pressure immediately proximal to the nidus of arteriovenous malformations may influence the frequency of spontaneous intracerebral hemorrhage. This study assessed the usefulness of transcranial Doppler ultrasound velocities as a noninvasive estimate of feeding mean arterial pressure. METHODS We studied 41 patients undergoing 73 staged treatments of...

متن کامل

Blood flow velocity and vasomotor reactivity in patients with arteriovenous malformations. A transcranial Doppler study.

BACKGROUND AND PURPOSE A large percentage of patients with a cerebral arteriovenous malformation (AVM) show focal neurological signs or have a history of intracranial hemorrhage. The present study used transcranial Doppler sonography to assess the clinical significance of hemodynamic disturbances in the intracranial arteries of patients with an AVM. METHODS Eighteen patients with untreated AV...

متن کامل

Evaluation of cerebrovascular disease by combined extracranial and transcranial Doppler sonography. Experience in 1,039 patients.

Results from 1,039 combined cervical and transcranial Doppler examinations are reported. Satisfactory transcranial signals were not found in 2.7% of the cases. Compared with angiography, the accuracy of transcranial criteria in assessing collateral flow over the circle of Willis was 94 and 88% for anterior and posterior circulation, respectively. The method also appeared very promising for dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 1990