Hybrid capture II, a new sensitive test for human papillomavirus detection. Comparison with hybrid capture I and PCR results in cervical lesions.

نویسندگان

  • C Clavel
  • M Masure
  • I Putaud
  • K Thomas
  • J P Bory
  • R Gabriel
  • C Quereux
  • P Birembaut
چکیده

AIM To test a new assay for the detection of human papillomavirus (HPV) DNA, hybrid capture II (HC II), compared with the previous commercialized hybrid capture I (HC I) and polymerase chain reaction (PCR) results on cervical scrapes from fresh cone excision biopsy samples. METHODS The three methods were used on cervical scrapes from 42 fresh cone excision biopsy samples. There were nine metaplastic and inflammatory lesions, five low grade lesions, and 28 high grade lesions. PCR was performed using the general primers GP5+/GP6+. The viral load of high risk HPV DNA was estimated by the ratio of relative light units to positive control values in the samples. RESULTS The sensitivity of HC I for the detection of high grade lesions was 71.4%, while it was 92.8% for HC II and 96.4% for the PCR. Considering only the absence of detectable cervical in situ neoplasia, the specificity was 88.9% for HC I, 66.7% for HC II, and 66.7% for PCR. With HC II, for a ratio of cervical sample to normal control of > 200, the sensitivity for the detection of high grade lesion was only 34.6% with a specificity of 66.7%. CONCLUSIONS HPV detection with the HC II assay is more sensitive than the previous HC I and represents a more convenient and easier test than PCR for routine use. Nevertheless the viral load estimated with this test cannot be a reliable predictive indicator of high grade lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of first- and second-generation digene hybrid capture assays for detection of human papillomaviruses associated with high or intermediate risk for cervical cancer.

In the present study we comparatively evaluated the first- and second-generation Digene Hybrid Capture assays for detection of human papillomaviruses (HPV) associated with high or intermediate risk for cervical cancer in cervical specimens. Concordant results were obtained with 468 of 483 (96.8%) specimens. All 15 specimens which gave repeatedly discordant results were positive by the second-ge...

متن کامل

Analysis of molecular biology techniques for the diagnosis of human papillomavirus infection and cervical cancer prevention Análise de técnicas de biologia molecular para o diagnóstico de infecções causadas por papilomavírus humanos e a prevenção do câncer cervical

The objective of the present study was to evaluate the usefulness of molecular methodologies to access human papillomavirus genome in the genital tract. Samples from 136 women aged 17 to 52 years old obtained from the Dr. Sérgio Franco Laboratories between 2000 and 2001, were analyzed by the hybrid capture assay and amplified by PCR with generic primers MY09/MY11 and specific primers for types ...

متن کامل

Comparison of PCR- and hybrid capture-based human papillomavirus detection systems using multiple cervical specimen collection strategies.

This study compared the performances of three human papillomavirus (HPV) detection tests with specimens collected by three alternative procedures. The HPV tests included the Hybrid Capture Tube test (HCT), the microplate-based Hybrid Capture II test (HC II), and the MY09-MY11 L1 consensus primer PCR-based assay. Initial cervical specimens were collected from study subjects with a broom device, ...

متن کامل

Comparison of human papillomavirus detection and typing by cycle sequencing, line blotting, and hybrid capture.

We compared the results of human papillomavirus (HPV) detection and typing from 781 cervical samples assayed by three methods: L1 consensus PCR followed by cycle sequencing, L1 consensus PCR with biotinylated primers followed by hybridization to a line blot, and Hybrid Capture assay. Both PCR assays used L1 consensus PCR with primers MY09 and MY11. We evaluated the amplification efficiencies of...

متن کامل

Evaluation of polymerase chain reaction (PCR) method and hybrid capture II (HCII) assay for the detection of human papillomavirus in cervical scrapings.

In order to investigate the reliability of detecting HPV DNA in cervical smears, we compared the performance of nested MY/GP PCR and FDA approved-Hybrid Capture II (HCII) using clinical cervical scrapings from 40 patients. It was found that PCR was more sensitive (81.8%) in comparison to HCII (36.4%) in detecting HPV although specificity of HCII was much higher (96.6%) than PCR (58.6%). The Neg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 51 10  شماره 

صفحات  -

تاریخ انتشار 1998