Beam Test Results for Single - and Double - Sided Silicon Detector Prototypes of the CMS Central Detector
نویسندگان
چکیده
Beam Test Results for Singleand Double-Sided Silicon Detector Prototypes of the CMS Central Detector O. Adriani5), E. Babucci8), N. Bacchetta7), G. Bagliesi9), P. Bartalini8), A. Basti9), G. M. Bilei8), D. Boemi4), L. Borrello4), F. Bosi9), R. Castaldi9), G. Castellini6), E. Catacchini5), U. Cazzola9), B. Checcucci8), C. Civinini5), D. Creanza3), R. D’Alessandro5), M. de Palma3), R. Dell’Orso9), R. Della Marina2), L. Fiore3), E. Focardi5), A. Gabbanini6), A. Giassi9), A. Giraldo7), L. Gorn11) M. Loreti7), G. Maggi3), G. Mantovani8), M. Meschini5), A. Messineo9), S. My3), G. Parrini5), M. Pieri5), F. Raffaelli9), G. Raso3), A. Santocchia8), E. Scarlini5), G. Selvaggi3), L. Servoli8), L. Silvestris3), A. Skassyrskaia9;a), F. Szoncso1), P. Tempesta3), M. Tesi6), G. Tonelli9;10), C. Vannini9), P. G. Verdini9), R. Wheadon9),
منابع مشابه
Double-sided Silicon Detectors using N-side Pad Readout for the CMS Silicon Inner Tracker
Double-sided silicon detector prototypes produced for the CMS inner tracker are described which divide the n-side into pads rather than strips. The signal routing to the readout electronics is made on a separate flexible z-print which is glued on the detector and then wire-bonded to the pads.
متن کاملPerformance of the Silicon Detectors for the CMS Barrel Tracker
The Compact Muon Solenoid is a detector designed for the Large Hadron Collider. High particle rates combined with a magnetic field of 4 T make particle tracking a challenge. The baseline is to use silicon pixel and microstrip detectors and microstrip gas chambers. This talk focuses on the barrel part of the silicon tracker. It is made of 816 modules (368 single-sided and 448 double-sided) arran...
متن کاملThe Silicon Tracking System of CMS
The paper describes the large silicon tracking system of CMS, one of the two general purpose detectors planned at the Large Hadron Collider of CERN. The system consists of three layers of silicon microstrip detectors instrumenting the interaction region as part of the Inner Tracking Detector of CMS. The expected performance of the system is discussed together with preliminary test beam results ...
متن کاملMeasurement of stereotactic beam data of 9 MV X-rays using diode detector
Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...
متن کاملIn - Beam Test of Double - Sided Silicon Strip Detector
The response of a double-sided silicon strip detector to a 3 GeV pion beam from the Proton Synchrotron at CERN is presented. Charge matching between the pulseheights from both sides, produced by the same traversing particle, is obtained with a resolution better than 5%. The spatial resolution is measured as a function of the incident angle of the projectile, varying from 15 m at normal incidenc...
متن کامل