Clinical and economic benefits of integrated pump/CGM technology therapy in patients with type 1 diabetes in Colombia.
نویسندگان
چکیده
OBJECTIVE To assess the long-term clinical and economic impact of integrated pump/CGM technology therapy as compared to multiple daily injections (MDI), for the treatment of type 1 diabetes (T1D) in Colombia. METHODS The CORE Diabetes Model was used to simulate a hypothetical cohort of patients with T1D. Mean baseline characteristics were taken from a clinical study conducted in Colombia and a healthcare payer perspective was adopted, with a 5% annual discount rate applied to both costs and outcomes. RESULTS The integrated pump/CGM improved mean life expectancy by 3.51 years compared with MDI. A similar increase occurred in mean quality-adjusted life expectancy with an additional 3.81 quality-adjusted life years (QALYs). Onset of diabetes-related complications was also delayed as compared to MDI, and mean survival time free of complication increased by 1.74 years with integrated pump/CGM. Although this increased treatment costs of diabetes as compared to MDI, savings were achieved thanks to reduced expenditure on diabetes-related complications. The estimated incremental cost-effectiveness ratio (ICER) for SAP was Colombian Pesos (COP) 44,893,950 (approximately USD$23,200) per QALY gained. CONCLUSIONS Improved blood glucose control associated to integrated pump/CGM results in a decreased incidence of diabetes-related complications and improves life expectancy as compared to MDI. Using recommended thresholds from the World Health Organization and previous coverage decisions about health technologies in Colombia, it is a cost-effective alternative to MDI for the treatment of type 1 diabetes in Colombia.
منابع مشابه
The role of continuous glucose monitoring in the care of children with type 1 diabetes
Continuous glucose monitoring (CGM), while a relatively new technology, has the potential to transform care for children with type 1 diabetes. Some, but not all studies, have shown that CGM can significantly improve hemoglobin A1c levels and reduce time spent in the hypoglycemic range in children, particularly when used as part of sensor-augmented pump (SAP) therapy. Despite the publication of ...
متن کاملContinuous Glucose Monitoring: A Perspective on Its Past, Present, and Future Applications for Diabetes Management
The transition from urinary glucose measurement to more sophisticated self-monitoring of blood glucose (SMBG) systems in the 1970s and 1980s dramatically changed the approach to and understanding of diabetes management (1). Innovations in the design and technology of portable blood glucose meters have become integral to the success of intensive treatment of both type 1 and type 2 diabetes, and ...
متن کاملPersonal continuous glucose monitoring (CGM) in diabetes management: review of the literature and implementation for practical use.
AIM Despite recent advances in diabetes therapy including the new long- and rapid-insulin analogs, insulin intensification strategies such as basal/bolus or pump therapy and sophisticated methods for insulin titration derived from the principles of functional insulin therapy, many patients fail to reach or maintain target glycosylated hemoglobin (HbA1c) values, putting them at increased risk fo...
متن کاملThe SWITCH study (sensing with insulin pump therapy to control HbA(1c)): design and methods of a randomized controlled crossover trial on sensor-augmented insulin pump efficacy in type 1 diabetes suboptimally controlled with pump therapy.
BACKGROUND studies investigating the effect of real-time continuous glucose monitoring (CGM) combined with pump therapy on glycemic outcomes in type 1 diabetes are increasing. Pump therapy is well established as a "gold standard" for insulin delivery, offering improvements over multiple daily insulin injections. However, there is still a proportion of subjects using continuous subcutaneous insu...
متن کاملIncremental Value of Continuous Glucose Monitoring When Starting Pump Therapy in Patients With Poorly Controlled Type 1 Diabetes
OBJECTIVE To compare the improvements in glycemic control associated with transitioning to insulin pump therapy in patients using continuous glucose monitoring versus standard blood glucose self-monitoring. RESEARCH DESIGN AND METHODS The RealTrend study was a 6-month, randomized, parallel-group, two-arm, open-label study of 132 adults and children with uncontrolled type 1 diabetes (A1C >or=8...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Endocrinologia y nutricion : organo de la Sociedad Espanola de Endocrinologia y Nutricion
دوره 63 9 شماره
صفحات -
تاریخ انتشار 2016