Perioperative Hypoalbuminemia Affects Improvement in Exercise Tolerance After Left Ventricular Assist Device Implantation.
نویسندگان
چکیده
BACKGROUND Although survival rates have improved for patients receiving implantable continuous flow left ventricular assist devices (I-CF LVAD), postoperative exercise tolerance levels are not necessarily satisfactory. METHODSANDRESULTS We enrolled 51 patients who had received an I-CF LVAD and underwent follow-up between 2006 and 2014; all patients underwent cardiopulmonary exercise testing 3 months following surgery: 26 (51%) patients achieved peak oxygen consumption (PV̇O2) ≥14 ml·kg(-1)·min(-1)and had significantly lower readmission rates for cardiovascular events than those with PV̇O2<14 ml·kg(-1)·min(-1)during 2 years of LVAD treatment (17 vs. 43%, P=0.033). Uni- and multivariate logistic regression analyses showed that the preoperative serum albumin (S-ALB) level was an independent predictor for PV̇O2≥14 ml·kg(-1)·min(-1)at 3 months (P=0.023, odds ratio 6.132). Patients with persistently normal S-ALB levels during the perioperative period had the lowest preoperative serum C-reactive protein level (S-CRP, 0.7±0.9 mg/dl), and the majority (77%) showed improved exercise tolerance. Conversely, patients with persistently low S-ALB levels during this period had the highest preoperative S-CRP level (2.8±1.2 mg/dl) and did not achieve the test endpoint. CONCLUSIONS Both pre- and postoperative low S-ALB impedes recovery of exercise tolerance after I-CF LVAD surgery, and this may be attributable to inflammatory responses caused by heart failure.
منابع مشابه
Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملCardiac improvement during mechanical circulatory support: a prospective multicenter study of the LVAD Working Group.
BACKGROUND Myocardial recovery after left ventricular assist device (LVAD) support has been reported. The LVAD Working Group Recovery Study was a prospective multicenter trial to assess the incidence of myocardial recovery in patients bridged to cardiac transplantation. METHODS AND RESULTS After LVAD implantation, patients were evaluated with the use of rest echocardiograms with partial LVAD ...
متن کاملLate-onset right ventricular failure in patients with preoperative small left ventricle after implantation of continuous flow left ventricular assist device.
BACKGROUND The continuous flow (CF) left ventricular assist device (LVAD) has replaced the pulsatile flow (PF) LVAD because of its advantages of better patient survival and higher quality of life. However, "late-onset right ventricular failure (RVF)" after CF LVAD implantation has emerged as an increasing concern, but little is known about the mechanism. METHODS AND RESULTS We retrospective...
متن کاملExtracorporeal membrane oxygenation as perioperative right ventricular support in patients with biventricular failure undergoing left ventricular assist device implantation.
OBJECTIVE Left-ventricular assist device (LVAD) implantation complicated by early right ventricle (RV) failure has a poor prognosis. This study details our center's experience with veno-arterial extracorporeal membrane oxygenation (ECMO) as perioperative RV support in patients with preoperative biventricular failure undergoing LVAD implantation. METHODS Ten patients, who underwent LVAD implan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 79 9 شماره
صفحات -
تاریخ انتشار 2015