Simultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist device
نویسندگان
چکیده
Many clinicians caring for patients with continuous flow left ventricular assist devices (CF-LVAD) use ramp right heart catheterization (RHC) studies to optimize pump speed and also to troubleshoot CF-LVAD malfunction. An investigational device, the ReliantHeart Heart Assist 5 (Houston, TX), provides the added benefit of an ultrasonic flow probe on the outflow graft that directly measures flow through the CF-LVAD. We performed a simultaneous ramp RHC and echocardiogram on a patient who received the above CF-LVAD to optimize pump parameters and investigate elevated flow through the CF-LVAD as measured by the flow probe. We found that the patient's hemodynamics were optimized at their baseline pump speed, and that the measured cardiac output via the Fick principle was lower than that measured by the flow probe. Right heart catheterization may be useful to investigate discrepancies between flow measured by a CF-LVAD and a patient's clinical presentation, particularly in investigational devices where little clinical experience exists. More data is needed to elucidate the correlation between the flow measured by an ultrasonic probe and cardiac output as measured by RHC.
منابع مشابه
3D Morphological Changes in LV and RV During LVAD Ramp Studies.
OBJECTIVES The purpose of this study was to investigate the differential impact of the 2 most commonly available left ventricular assist device (LVAD) types on the right ventricle (RV) and left ventricle (LV) using 3-dimensional (3D) echocardiography-based analysis of ventricular morphology. BACKGROUND LVADs have emerged as common therapy for advanced heart failure. Recent data suggest that t...
متن کاملHemodynamic Ramp Tests in Patients With Left Ventricular Assist Devices.
OBJECTIVES This study tested whether combined invasive hemodynamic and echocardiographic ramp tests can help optimize patient management. BACKGROUND Guidelines for optimizing speed and medications in continuous flow ventricular assist device (cfLVAD) patients are mainly based on expert opinion. METHODS Thirty-five cfLVAD patients (21 HeartMate II [Thoratec, Pleasanton, California] and 14 HV...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملEchocardiographic Evaluation of Hemodynamics in Patients With Systolic Heart Failure Supported by a Continuous-Flow LVAD.
BACKGROUND Hemodynamics assessment is important for detecting and treating post-implant residual heart failure, but its accuracy is unverified in patients with continuous-flow left ventricular assist devices (CF-LVADs). OBJECTIVES We determined whether Doppler and 2-dimensional transthoracic echocardiography reliably assess hemodynamics in patients supported with CF-LVADs. METHODS Simultane...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کامل