Narrow elastic disposable tourniquet (Hemaclear®) vs. traditional wide pneumatic tourniquet for creation or revision of hemodialysis angioaccesses.

نویسندگان

  • Pierre Bourquelot
  • Bernard I Levy
چکیده

PURPOSE To choose the best arterial tourniquet for angioaccess surgery. METHODS Preventive hemostasis with an arterial tourniquet prevents bleeding and provides better visualization. The surgeon may currently use a traditional wide nonsterile inflatable pneumatic cuff after exsanguination with an Esmarch bandage or a disposable sterile narrow elastic silicone ring (HemaClear®), available in different sizes according to the patient's limb circumference and blood pressure. RESULTS The latter is easily rolled up the upper limb after surgical draping, to achieve exsanguination and occlusion of the proximal brachial artery, thus providing a wide sterile field that is most useful for upper arm vein superficialization or arteriovenous fistula (AVF) revision. Although rare, neurological complications must be prevented by limiting the compressive force applied to the tissues to occlude the arteries and the veins. Such tissues are almost non-compressible but deformable; thus, they may be elongated and damaged, mostly at both extremities of the tourniquet, especially the nerves. The compressive force (kg) applied to the limb by the cuff is the product of the cuff pressure (mm Hg) imposed and the surface (cm²) of the skin in contact with the cuff. Reduction of the cuff surface results in reduction of the volume of tissue beneath the cuff and therefore in limitation of the compressive force. CONCLUSIONS From a theoretical point of view and from clinical data, it seems therefore reasonable to recommend the use of a narrower cuff size and, for practical reasons, the silicon ring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary Embolism After Application of a Sterile Elastic Exsanguination Tourniquet.

Sterile elastic exsanguination tourniquets (HemaClear; OHK Medical Devices, Haifa, Israel) are relatively new on the market but are widely used because of the ease and speed of their application. The sterile elastic exsanguination tourniquet consists of a silicon ring wrapped in a stockinet sleeve with pull straps. The physician places the ring on the patient's fingers or toes and then pulls th...

متن کامل

Tourniquet pain in a volunteer study: effect of changes in cuff width and pressure.

This study examines the relationship between pneumatic tourniquet cuff size, occlusion pressure and the resulting pain. Two tourniquet cuff widths were used, a wide (14 cm) and a narrow cuff (7 cm). Twenty volunteers were divided into two groups for tourniquet application: a pressure group in which the tourniquet was inflated to a pressure equal to the systolic pressure + 100 mmHg, and a satura...

متن کامل

The Effect of the Silicone Ring Tourniquet and Standard Pneumatic Tourniquet on the Motor Nerve Conduction, Pain and Grip Strength in Healthy Volunteers

  Background: The pneumatic tourniquet (PT) is routinely used in upper and lower limb operations by most orthopaedic surgeons. The silicone ring tourniquet (SRT) was introduced in clinical practice the last decade. Clinical as well comparative studies in volunteers concerning its safety and efficacy have been published. The aim of this study was to investigate the postoperative effect of the si...

متن کامل

Skin protection underneath the pneumatic tourniquet during total knee arthroplasty: a randomized controlled trial of 92 patients.

BACKGROUND The use of a pneumatic tourniquet to obtain a bloodless field during a total knee arthroplasty (TKA) allows the surgeon to work with greater technical precision in a safe, clear environment. Despite the benefits of surgical tourniquets and many advances in tourniquet equipment, their use is not without risk and complications may still occur. The primary aim of this study was to deter...

متن کامل

Measurement of hazardous pressure levels and gradients produced on human limbs by non-pneumatic tourniquets

This paper reports on existing and novel transducers for improved quantitative investigations of the levels of applied pressures and pressure gradients produced on human limbs by non-pneumatic tourniquet straps, and by non-pneumatic elastic bandages and elastic rolls when used as tourniquets, for comparison to benchmark data for pneumatic tourniquet cuffs commonly used in surgery at present.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of vascular access

دوره 17 3  شماره 

صفحات  -

تاریخ انتشار 2016