BACKGROUND Despite the enhanced properties of the second-generation drug-eluting stent (DES), its association with neoatherosclerosis has not been sufficiently evaluated. Therefore, we sought to evaluate and compare neoatherosclerosis in second-generation DESs to first-generation DESs. METHODS AND RESULTS A total of 212 DES-treated patients with >50% percent neointimal cross-sectional area stenosis were retrospectively enrolled from the Korean multicenter optical coherence tomography (OCT) registry. Within this population, 111 patients had a second-generation DES (40 zotarolimus, 36 everolimus, and 35 biolimus) and 101 patients had a first-generation (65 sirolimus and 36 paclitaxel) DES. Neoatherosclerosis on OCT was defined as neointima formation with the presence of lipids or calcification. OCT-determined neoatherosclerosis was identified in 27.4% (58/212) of all DES-treated lesions. The frequency of neoatherosclerosis increased with the stent age. Stent age was shorter in the second-generation DES group (12.4 months versus 55.4 months, P<0.001), and neoatherosclerosis was less frequently observed in that group (10.8% versus 45.5%, P<0.001). However, after adjusting for cardiovascular risk factors, chronic kidney disease (odds ratio, 4.113; 95% confidence interval, 1.086-15.575; P=0.037), >70 mg/dL of low-density cholesterol at follow-up OCT (odds ratio, 2.532; 95% confidence interval, 1.054-6.084; P=0.038), and stent age (odds ratio, 1.710; 95% confidence interval, 1.403-2.084; P<0.001) were all independent predictors for neoatherosclerosis, whereas the type of DES (first- versus second-generation) was not. Patients with neoatherosclerosis showed a higher rate of acute coronary syndrome at follow-up OCT (19.0% versus 3.9%, respectively, P=0.001). CONCLUSIONS The second-generation DES is not more protective against neoatherosclerosis compared with the first-generation DES.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical Coherence Tomographic Observation of Morphological Features of Neointimal Tissue after Drug-Eluting Stent Implantation

PURPOSE The impacts of different time courses and the degree of neointimal growth on neointimal morphology have not yet been sufficiently investigated. Therefore, we evaluated the morphological features of neointimal tissue after drug-eluting stent (DES) implantation using optical coherence tomography (OCT). MATERIALS AND METHODS The morphological features of neointimal tissue in stented segm...

متن کامل

Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation.

BACKGROUND We report findings from optical coherence tomography (OCT) of in-stent neoatherosclerosis as a cause of drug-eluting stent (DES) failure. METHODS AND RESULTS Optical coherence tomography and grayscale and virtual histology intravascular ultrasound were performed in 50 patients (30 stable, 20 unstable angina) with 50 DES in-stent restenosis lesions and intimal hyperplasia >50% of st...

متن کامل

Stent Evaluation with Optical Coherence Tomography

Optical coherence tomography (OCT) has been recently applied to investigate coronary artery disease in interventional cardiology. Compared to intravascular ultrasound, OCT is able to visualize various vascular structures more clearly with higher resolution. Several validation studies have shown that OCT is more accurate in evaluating neointimal tissue after coronary stent implantation than intr...

متن کامل

Optical coherence tomography characteristics of in-stent restenosis are different between first and second generation drug eluting stents☆

Aims Characterization of neointimal tissue is essential to understand the pathophysiology of in-stent restenosis (ISR) after drug eluting stent (DES) implantation. Using optical coherence tomography (OCT), we compared the morphologic characteristics of ISR between first and second generation DES. Methods and Results OCT was performed in 66 DES-ISR, defined as > 50% angiographic diameter steno...

متن کامل

Long-term outcomes of neointimal hyperplasia without neoatherosclerosis after drug-eluting stent implantation.

OBJECTIVES The aim of this study was to investigate the correlation between in-stent neointimal tissue without features of neoatherosclerosis and long-term clinical outcomes. BACKGROUND Recent studies have reported differential morphological characteristics of in-stent neointimal tissue assessed by optical coherence tomography (OCT). METHODS The study population consisted of 336 patients wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 8 2  شماره 

صفحات  -

تاریخ انتشار 2015