General design approach and practical realization of decoupling matrices for parallel transmission coils.

نویسندگان

  • Zohaib Mahmood
  • Patrick McDaniel
  • Bastien Guérin
  • Boris Keil
  • Markus Vester
  • Elfar Adalsteinsson
  • Lawrence L Wald
  • Luca Daniel
چکیده

PURPOSE In a coupled parallel transmit (pTx) array, the power delivered to a channel is partially distributed to other channels because of coupling. This power is dissipated in circulators resulting in a significant reduction in power efficiency. In this study, a technique for designing robust decoupling matrices interfaced between the RF amplifiers and the coils is proposed. The decoupling matrices ensure that most forward power is delivered to the load without loss of encoding capabilities of the pTx array. THEORY AND METHODS The decoupling condition requires that the impedance matrix seen by the power amplifiers is a diagonal matrix whose entries match the characteristic impedance of the power amplifiers. In this work, the impedance matrix of the coupled coils is diagonalized by a successive multiplication by its eigenvectors. A general design procedure and software are developed to generate automatically the hardware that implements diagonalization using passive components. RESULTS The general design method is demonstrated by decoupling two example parallel transmit arrays. Our decoupling matrices achieve better than -20 db decoupling in both cases. CONCLUSION A robust framework for designing decoupling matrices for pTx arrays is presented and validated. The proposed decoupling strategy theoretically scales to any arbitrary number of channels. Magn Reson Med 76:329-339, 2016. © 2015 Wiley Periodicals, Inc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A General Design Approach and Practical Realization of Decoupling Matrices for Parallel Transmission Coils

Purpose—In a coupled parallel transmit (pTx) array, the power delivered to a channel is partially distributed to other channels because of coupling. This power is dissipated in circulators resulting in a significant reduction in power efficiency. In this paper, a technique for designing robust decoupling matrices interfaced between the RF amplifiers and the coils is proposed. The decoupling mat...

متن کامل

Novel optically tunable capacitor for RF safe tuning and decoupling of intravascular MR coils

S. Weiss, T. Uelzen, G. Pantel, J. Mueller Philips Research Laboratories, Hamburg, Germany, Department of Micro Systems Technology, Hamburg University of Technology, Hamburg, Germany, MRI Devices Daum GmbH, Schwerin, Germany Objective: The motivation for the application of intravascular imaging coils is to gain high SNR images from a local area. To maximize SNR, proper tuning and matching of su...

متن کامل

New horizons in MR technology: RF coil designs and trends.

Parallel imaging techniques have developed very rapidly, and realization of their full potential has required the design of magnetic resonance (MR) scanners with ever-increasing numbers of receiver channels (32 to 128). In particular, 1.5- and 3-Tesla fast MR imaging applications are now used in everyday clinical practice. Both strengths require maximum achievable signal-to-noise ratio (SNR) an...

متن کامل

Mutual Inductance Calculation between Misalignment Coils for Wireless Power Transfer of Energy

In this paper we present a detailed theoretical analysis of lateral and angular misalignment effects in RF coils. Radio-frequency (RF) coils are used extensively in the design of implantable devices for transdermal power and data transmission. A design procedure is established to maximize coil coupling for a given configuration to reduce the effects of misalignment on transmission efficiency. F...

متن کامل

Transceive Stripline Arrays for Ultra High Field Parallel Imaging Applications

G. Adriany, P. Van de Moortele, F. Wiesinger, P. Andersen, J. Strupp, X. Zhang, C. J. Snyder, W. Chen, K. P. Pruessmann, P. Boesiger, J. T. Vaughan, K. Ugurbil Center for MR Research, University of Minnesota Medical School, Minneapolis, United States, Institute for Biomedical Engineering, University and ETH Zurich, Switzerland We present four and eight channel transceive stripline arrays for ul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 76 1  شماره 

صفحات  -

تاریخ انتشار 2016