Active Angular Alignment of Gauge Blocks in Double-Ended Interferometers

نویسندگان

  • Zdenek Buchta
  • Simon Rerucha
  • Václav Hucl
  • Martin Cízek
  • Martin Sarbort
  • Josef Lazar
  • Ondrej Cíp
چکیده

This paper presents a method implemented in a system for automatic contactless calibration of gauge blocks designed at ISI ASCR. The system combines low-coherence interferometry and laser interferometry, where the first identifies the gauge block sides position and the second one measures the gauge block length itself. A crucial part of the system is the algorithm for gauge block alignment to the measuring beam which is able to compensate the gauge block lateral and longitudinal tilt up to 0.141 mrad. The algorithm is also important for the gauge block position monitoring during its length measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Principles of calculating the dynamical response of misaligned complex resonant optical interferometers

In the long-baseline laser interferometers for measuring gravitational waves that are now under construction, understanding the dynamical response to small distortions such as angular alignment fluctuations presents a unique challenge. These interferometers comprise multiple coupled optical resonators with light storage times approaching 100 m. We present a basic formalism to calculate the freq...

متن کامل

Analysis of Frequency Leakage in Different Optical Paths of Nano-Metrology Systems Based on Frequency-Path Models

The drawing of frequency-path (F-P) models of optical beams is an approach for nonlinearity analysis in nano-metrology systems and sensors based on the laser interferometers. In this paper, the frequency-path models of four nano-metrology laser interferometry systems are designed, analyzed and simulated, including ...

متن کامل

On the gauge-invariance of gravitational waves

The aim of this paper is to show the gauge-invariance on the response of interferometers to gravitational waves (GWs). In this process, after a review of results on the Tranverse-Traceless (TT) gauge, where, in general, the theoretical computations on GWs are performed, which is due for completness, we analyse the gauge of the local observer, which represents the gauge of a laboratory environme...

متن کامل

Generalized gauge-invariance for gravitational waves

The aim of this paper is to show the gauge-invariance on the response of interferometers to gravitational waves (GWs). In this process, after a review of results on the Tranverse-Traceless (TT) gauge, where, in general, the theoretical computations on GWs are performed, which is due for completness, we analyse the gauge of the local observer, which represents the gauge of a laboratory environme...

متن کامل

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2013