Effects of pulsation frequency and endothelial integrity on enhanced arterial transmural filtration produced by pulsatile pressure.

نویسندگان

  • Jonathan P Alberding
  • Ann L Baldwin
  • Jennifer K Barton
  • Elizabeth Wiley
چکیده

The role of the endothelium in regulating transmural fluid filtration into the artery wall under pulsatile pressure and the effects of changes in pulsatile frequency on filtration have received little attention. Previous experiments (Alberding JP, Baldwin AL, Barton JK, and Wiley E. Am J Physiol Heart Circ Physiol 286: H1827-H1835, 2004) demonstrated significantly increased filtration after initial onset of pulsatile pressure compared with that predicted by using parameters measured under steady pressure. To determine the role of the endothelium in this phenomenon, the following experiments were performed on five New Zealand White rabbits (anesthetized with 30 mg/kg pentobarbital sodium). One of each pair of carotid arteries was deendothelialized, and filtration measurements under steady and pulsatile pressure were compared with those made in intact vessels (Alberding JP, Baldwin AL, Barton JK, and Wiley E. Am J Physiol Heart Circ Physiol 286: H1827-H1835, 2004). To determine the effect of increasing pulsatile frequency on arterial filtration, transmural filtration was measured by using pulsatile pressure frequencies of 1 Hz, followed by 2 Hz, in another set of intact arteries (6 arteries and 3 animals). For deendothelialized vessels, the initial increase in filtration after onset of pulsatility was similar to that observed in intact vessels, but the subsequent reduction in filtration was less abrupt. When pulsatile frequency was increased from 1 to 2 Hz in intact arteries, an initial increase in filtration was observed, similar to that obtained after onset of pulsatile pressure subsequent to a steady pressure. The observed responses of arteries to pulsatile pressure, with and without endothelium, or undergoing a frequency change, suggest a dynamic role for the endothelium in regulating transvascular transport in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

Cerebrospinal Pulsation Hydrodynamics in a 2D Simulation of Brain Ventricles

In this article, dynamics of the cerebrospinal fluid (CSF) was studied, using computational fluid dynamics. Using MRI images of two special cases, a 2-dimensional model of the ventricular system was made. CSF velocity and pressure distribution in ventricular system have high importance since the flow pattern of this liquid has an important effect on intracranial pressure, i.e., ICP, which has a...

متن کامل

Hemodynamics and the vascular endothelial cytoskeleton

Although there is considerable evidence to suggest that hemodynamics play an important role in vascular disease processes, the exact mechanisms are unknown. With this in mind, we have designed a pulsatile perfusion apparatus which reproducibly delivers pulsatile hemodynamics upon freshly excised canine carotid arteries in vitro. Quantifiable simulations included normotension with normal or lowe...

متن کامل

Cardiovascular responses to various pulsatile pressures in the carotid sinus.

SCHMIDT,ROBERT M., MAMORUKUMADA,AND KIICHI SAGAWA. Curdiovascular responses to various pulsatile pressures in the carotid sinus. Am. J. Physiol. 223 (1): l-7. 1972.-To extend the knowledge of the carotid sinus reflex, we forced the isolated sinuses of anesthetized dogs with sinusoidal (pulsatile) pressures using multiple combinations of mean level, amplitude, and frequency of pulsation. The ref...

متن کامل

Onset of pulsatile pressure causes transiently increased filtration through artery wall.

Convective fluid motion through artery walls aids in the transvascular transport of macromolecules. Although many measurements of convective filtration have been reported, they were all obtained under constant transmural pressure. However, arterial pressure in vivo is pulsatile. Therefore, experiments were designed to compare filtration under steady and pulsatile pressure conditions. Rabbit car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 289 2  شماره 

صفحات  -

تاریخ انتشار 2005