Automated cardiac flow measurement by digital colour Doppler echocardiography.

نویسنده

  • T Shiota
چکیده

In the 1980s, the development of Doppler echocardiography, especially pulsed wave Doppler techniques, provided significant progress in determining cardiac flow volumes. The pulsed wave Doppler method is based on a simple mathematical principle, which multiplies a flow area by its velocity during the flow time (velocity–time integral) to estimate a flow volume. This Doppler method assumes a spatially flat flow velocity distribution and a constant flow area during the entire time of flow. However, the spatial velocity profile is not necessarily flat and the flow area may change during the time of flow. In the 1990s, a digitally automated cardiac flow measurement method was developed to overcome these shortcomings of the conventional pulsed Doppler method. This new method uses not only a single central point but also multiple Doppler points in space along the diameter of the flow; it also uses several imaging frames during the time of flow, accounting for the temporal change in the flow area (that is, not assuming a constant flow area). In addition, the calculation does not require manual tracing of the Doppler velocity nor the measurement of flow diameter. Thus, the actual use of this automated method in clinical settings is simpler and easier than the conventional pulsed Doppler method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CARDIOVASCULAR MEDICINE Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation

Background: The recently introduced automated cardiac flow measurement (ACM) technique provides a quick and an accurate automated calculation of stroke volume and cardiac output. This is obtained by spatio-temporal integration of digital Doppler velocity profile data. Objective: To evaluate the use of the ACM method in the non-invasive assessment of aortic regurgitant volume and per cent regurg...

متن کامل

Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation.

BACKGROUND The recently introduced automated cardiac flow measurement (ACM) technique provides a quick and an accurate automated calculation of stroke volume and cardiac output. This is obtained by spatio-temporal integration of digital Doppler velocity profile data. OBJECTIVE To evaluate the use of the ACM method in the non-invasive assessment of aortic regurgitant volume and per cent regurg...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

Diagnosis of ventricular septal rupture after myocardial infarction: value of colour flow mapping.

Twenty patients with ventricular septal rupture after myocardial infarction were investigated by cross sectional echocardiography with integrated pulsed and continuous wave Doppler and colour flow mapping. Confirmatory cardiac catheterisation was performed in 12 patients. Eighteen patients had surgical repair with inspection of the defect. Six patients in whom recurrent ventricular septal ruptu...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 88 3  شماره 

صفحات  -

تاریخ انتشار 2002