Quantitative, non-invasive assessment of ventricular septal defect shunt flow by measuring proximal isovelocity surface area on colour Doppler mapping.
نویسندگان
چکیده
OBJECTIVE To determine whether the proximal isovelocity surface area (PISA) method could be applied to estimate the magnitude of ventricular septal defect (VSD) shunt flow. DESIGN Prospective analysis of clinical, echocardiographic, and angiographic data. SETTING University hospital. PATIENTS 14 children with VSD. METHODS Colour Doppler images of VSD shunt flow were obtained in parasternal long axis view, four chamber view or both, adjusted to provide the best imaging of flow. The VSD shunt flow rate and shunt volume were calculated as follows: shunt flow rate (SFR) = 2 pi r2 V/BSA in ml/s/m2; shunt volume = SFR x shunt duration time. The shunt volume, shunt fraction, and pulmonary to systemic flow ratio (Qp:Qs) were confirmed by cardiac catheterisation. RESULTS There was a correlation between shunt variables determined by PISA and those by catheterisation, including shunt volume (r = 0.78, P = 0.001) and shunt fraction (r = 0.74, P = 0.003). Qp:Qs was also significantly correlated with SFR (r = 0.79, P = 0.0007). The SFR was significantly different between the four patients with Qp:Qs < 2.0 (mean (SD) 54 (33) ml/s/m2) and the 10 patients with Qp:Qs > 2.0 (186 (69) ml/s/m2) (P = 0.004). CONCLUSIONS These data suggest that the PISA method is a reliable non-invasive investigation for the quantitative assessment of VSD shunt flow and provides important information for decisions regarding surgical repair.
منابع مشابه
Should clinical cardiologists incorporate the proximal isovelocity surface area (PISA) method into their ever enlarging armamentarium?
Should clinical cardiologists incorporate the proximal isovelocity surface area (PISA) method into their ever enlarging armamentarium? This issue contains a paper comparing measurement of ventricular septal defect shunt ratio by a proximal iso-velocity surface area technique (usually abbreviated as PISA) method and by the Fick method.' The authors used some shortcuts in the PISA method, perhaps...
متن کاملQuantitative assessment of severity of ventricular septal defect by three-dimensional reconstruction of color Doppler-imaged vena contracta and flow convergence region.
BACKGROUND The aim of the present study was to investigate the feasibility and potential value of the computer-controlled, 3D, echocardiographic reconstruction of the color Doppler-imaged vena contracta (CDVC) and the flow convergence (FC) region as a means of accurately and quantitatively estimating the severity of a ventricular septal defect (VSD). METHODS AND RESULTS We performed a 3D reco...
متن کاملQuantitative, noninvasive assessment of patent ductus arteriosus shunt flow by measuring proximal isovelocity surface area on color Doppler imaging.
BACKGROUND We evaluated the hemodynamic status of patent ductus arteriosus (PDA) by measuring vena contracta width (VCW) and effective shunt orifice area (ESOA) using proximal isovelocity surface area (PISA) on color Doppler imaging. METHODS AND RESULTS: Study subjects were 21 patients with PDA (mean age, 3.6 years). We measured VCW (mm/m(2)) and ESOA (cm(2)) by the PISA method using echocardio...
متن کاملLocalisation of ventricular septal defects by simultaneous display of superimposed colour Doppler and cross sectional echocardiographic images.
Precise non-invasive localisation of the site of a small ventricular septal defect was attempted using a new technique that simultaneously combines conventional cross sectional echocardiography with a Doppler system by superimposing the colour coded direction and velocity of blood flow directly on to real time ultrasound images. Twenty three patients with unoperated ventricular septal defects a...
متن کاملSensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects.
Twenty nine patients (aged from three months to 37 years) with confirmed or suspected ventricular septal defects were studied separately by three examiners who used colour flow mapping and imaging, or continuous wave Doppler and imaging, or a combined reference examination. Colour flow mapping identified 19 of the 25 patients with a ventricular septal defect, continuous wave Doppler echocardiog...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 78 3 شماره
صفحات -
تاریخ انتشار 1997