Measurement of vasomotor reserve in the transcranial Doppler-CO(2) test using an ultrasound contrast agent (Levovist).
نویسندگان
چکیده
BACKGROUND AND PURPOSE Determination of vasomotor reserve (VMR) with the transcranial Doppler-CO(2) (TCD-CO(2)) test is used to assess the risk of impending cerebral ischemia in patients with high-grade stenosis or occlusion of the internal carotid artery. In patients with a poor temporal window, however, this examination is limited. The aim of this study therefore was to examine whether the use of an ultrasound contrast agent (USCA) influences the results of the TCD-CO(2) test. METHODS In the first part of the study, 6 control subjects and 20 patients were examined with the TCD-CO(2) test. The VMR was determined first without the application of a contrast agent and then with continuous infusion of an USCA (Levovist, 300 mg/mL, 1 mL/min). In the second part of the study, 2 tests without USCA were performed in each of 13 patients and 2 tests with USCA infusion were performed in each of 12 patients. Statistical analysis included differences between the VMR determined with the 2 comparative measurements (VMR), the mean (M(VMR)), and SD. RESULTS Based on the mean difference, the TCD-CO(2) test produced the same results with and without USCA (M(VMR) 1.8%), although the differences showed a wide distribution (2 SDs, +/-20.7%). Similar spreads were seen in repeated determinations of VMR in the same patient without USCA (2 SDs, +/-20.0%), whereas the distribution under continuous USCA infusion was considerably smaller (2 SDs, +/-8.2%). CONCLUSIONS The TCD-CO(2) test can be performed with continuous infusion of an USCA without influencing the results. Even with a good temporal window, the results of the TCD-CO(2) test show better reproducibility and thus better reliability if an USCA is used.
منابع مشابه
Quantitative evaluation of contrast enhanced transcranial Doppler signal using galactose based echo-contrast agent in dogs.
Transcranial Doppler ultrasonography (TCD) is hindered by insufficient ultrasound penetration through the temporal bone. The use of echo-contrast agents to enhance the Doppler signal is an important step toward the solution of this problem. The aim of the present study was to investigate the tolerability and diagnostic value of the intravenous echo-contrast agent, Levovist. Levovist was adminis...
متن کاملEcho contrast-enhanced transcranial ultrasound: frequency of use, diagnostic benefit, and validity of results compared with MRA.
BACKGROUND AND PURPOSE The present study was undertaken to determine the frequency of use of the ultrasound contrast agent (UCA) Levovist in routine transcranial ultrasound (TU). Additionally, we evaluated the diagnostic validity of contrast-enhanced TU using 3-dimensional time of flight MR angiography. METHODS Indication for the UCA was an insufficient evaluation of the intracranial arteries...
متن کاملOriginal Contributions Clinical and Hemodynamic Aspects of Low-Flow Infarcts
We used single-photon emission computed tomography to measure cerebral blood flow, cerebral blood volume, and cerebral perfusion reserve and transcranial Doppler sonography with CO, stimulation to assess hemispheric vasomotor reactivity in 37 patients and in normal controls. Computed tomography and magnetic resonance imaging were performed to differentiate morphologically low-flow infarcts (n=1...
متن کاملMRA contrast bolus timing with ultrasound bubbles.
The purpose of this study was to determine the feasibility of using an ultrasound contrast agent test bolus to determine optimum bolus timing for three-dimensional (3D) gadolinium (Gd)-enhanced magnetic resonance angiography (MRA). Small test doses of ultrasound contrast agent (0.3 ml Optison) were injected intravenously followed immediately by a 20 ml saline flush. Arrival of the contrast agen...
متن کاملStimulated acoustic emission detected by transcranial color doppler ultrasound : a contrast-specific phenomenon useful for the detection of cerebral tissue perfusion.
BACKGROUND AND PURPOSE Experimental and clinical data suggest that insonation of echo-contrast agents with high acoustical power produces disintegration of microbubbles, resulting in a pseudo-Doppler phenomenon called stimulated acoustic emission (SAE). The purpose of this study was to investigate whether SAE might be detected by transcranial color Doppler imaging and whether these signals migh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 32 6 شماره
صفحات -
تاریخ انتشار 2001