Fetal pulse oximetry for fetal assessment in labour.
نویسندگان
چکیده
BACKGROUND Fetal pulse oximetry (FPO) may contribute to the evaluation of fetal well-being during labour. OBJECTIVES To compare the effectiveness and safety of FPO with conventional surveillance techniques, using the results of randomised controlled trials. SEARCH STRATEGY We searched the Cochrane Pregnancy and Childbirth Group trials register (31 July 2004) and conducted a systematic literature search of MEDLINE (1994 to July 2004), EMBASE (1994 to July 2004) and Current Contents (1994 to July 2004). SELECTION CRITERIA All published and unpublished randomised controlled trials (RCTs) that compared maternal and fetal/neonatal/infant outcomes when FPO was used in labour, with or without concurrent use of conventional fetal surveillance, compared with using cardiotocography (CTG) alone. DATA COLLECTION AND ANALYSIS Two independent reviewers performed data extraction. Analyses were performed on an intention-to-treat basis. We sought additional information from the investigators of the one reported trial. MAIN RESULTS One published RCT (comparing FPO and CTG with CTG alone) was included; and two ongoing RCTs were identified. The single included RCT reported on 1010 cases. Unpublished pilot data were available for some outcomes to give a total of 1190 cases. There was no difference in the overall caesarean section rate between the two groups (relative risk (RR) 1.12, 95% confidence interval (CI) 0.91 to 1.37). There were less caesarean sections for nonreassuring fetal status in the FPO plus CTG group compared with the CTG only group (RR 0.45, 95% CI 0.28 to 0.72). The only reported neonatal seizure occurred in the CTG only group (RR 0.29 95% CI 0.01 to 7.08). Use of FPO with CTG decreased operative delivery (caesarean section, forceps, vacuum) for nonreassuring fetal status (RR 0.71, 95% CI 0.55 to 0.93) compared with CTG alone. No differences were seen for overall operative deliveries, endometritis, intrapartum or postpartum haemorrhage, uterine rupture, low Apgar scores, umbilical arterial pH or base excess, admission to the neonatal intensive care unit or fetal/neonatal death. REVIEWERS' CONCLUSIONS The one published RCT reported that FPO decreased the caesarean section rate and operative delivery rates for nonreassuring fetal status, without adversely affecting maternal or fetal/neonatal outcomes. However, no difference was seen in the overall caesarean section (CS) or operative delivery rates because more CS were performed for dystocia in the FPO group. Further RCTs may address dystocia in labours monitored with FPO, maternal satisfaction with fetal monitoring and labour, long-term neurodevelopmental outcome of infants who exhibited nonreassuring fetal status in labour and costs of FPO.
منابع مشابه
Fetal pulse oximetry: the European experience
Pulse oximetry is a technique of fetal monitoring during labour based on non-invasive measurement of fetal arterial oxygen saturation. It has been shown in animal studies that metabolic acidosis occurred for a fetal arterial oxygen saturation below 30%. One of the main debates during initial experience in humans, was focused on the adequate cut-off for intervention (or non-intervention), and th...
متن کاملTrans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry.
Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to elect...
متن کاملRational approach to electronic fetal monitoring during labour in 'all' resource settings
Electronic fetal monitoring (EFM) involves the use of cardiotocograph (CTG) to asses fetal wellbeing during labour in order to detect intrapartum fetal hypoxia early so as to institute timely and appropriate action. Indeed, when CTG was introduced into obstetric practice in the 1960s, it was expected to prevent perinatal brain injury and reduce the incidence of short term (neonatal admissions, ...
متن کاملFetal health surveillance in labour.
OBJECTIVE This guideline defines the standards pertaining to the application and documentation of fetal surveillance in labour that will decrease the incidence of birth asphyxia while maintaining the lowest possible rate of obstetrical intervention. Both high- and low-risk obstetrical populations are considered. It is intended that this guideline could be used by all persons providing intrapart...
متن کاملAccuracy of fetal pulse oximetry and pitfalls in measurements.
Pulse oximetry is a technique for estimating arterial oxygen saturation continuously and non-invasively. Reflectance pulse oximetry might become useful for monitoring the fetus during labour but it is much more susceptible to all kinds of physiological variations than the well-established transmission pulse oximetry for neonatal or adult monitoring. This review focuses on the accuracy of reflec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Cochrane database of systematic reviews
دوره 10 شماره
صفحات -
تاریخ انتشار 2004