Myocardial iron quantification using modified Look-Locker inversion recovery (MOLLI) T1 mapping at 3 Tesla
نویسندگان
چکیده
Background Quantification of myocardial iron overload is critical for the management of patients with hemochromatosis. The effects of excess iron on T1 and T2* relaxation times correlate directly with tissue iron concentration. T2* became the clinical standard at 1.5T as it can be easily obtained in a fast one breath-hold ECG gated multi-echo GRE sequence. At 3T, however, T2* quantification can be limited by pronounced susceptibility artifacts and signal sampling restraints due to shorter T2* times at higher iron concentrations . Since myocardial T1 time is up to thirty times longer than T2*, it can be quantified with short echo-time inversionrecovery sequences even at high iron concentrations, and is less sensitive to susceptibility artifacts. We aimed to validate a recently developed modified LookLocker inversion recovery (MOLLI) sequence to quantify myocardial T1 in healthy controls and patients with iron overload at 3T, comparing to standard GRE based multi-echo T2* times at 1.5T.
منابع مشابه
Shortened modified look-locker inversion recovery for myocardial T1 mapping in healthy volunteers: determination of reference T1 relaxation times at 3 Tesla MR according to different contrast injection methods
Background Reference preand post-contrast T1 values of myocardium have been reported at 1.5T but those values at 3T have not been fully established. Additionally, the physical properties of gadolinium contrast agents significantly affect the myocardial voxel T1 value. There have been two different contrast injection methods in the literatures. The aim of our study was to establish preand post-c...
متن کاملT1 mapping using a saturation recovery single-shot acquisition at 3 Tesla MRI in differentiation of normal myocardium from hypertrophic cardiomyopathy
Background Background Diffuse myocardial fibrosis is characteristic feature of hypertrophic cardiomyopathy (HCM). T1 mapping may enable non-invasive evaluation of diffuse myocardial fibrosis in HCM. There have been many studies that T1 mapping using a modified Look-Locker inversion recovery (MOLLI) sequence. However, there have been few studies using a SASHA for T1 mapping at 3 Tesla MRI. The p...
متن کاملModified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart.
A novel pulse sequence scheme is presented that allows the measurement and mapping of myocardial T1 in vivo on a 1.5 Tesla MR system within a single breath-hold. Two major modifications of conventional Look-Locker (LL) imaging are introduced: 1) selective data acquisition, and 2) merging of data from multiple LL experiments into one data set. Each modified LL inversion recovery (MOLLI) study co...
متن کاملImproved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice
OBJECT To develop and evaluate a 2D modified Look-Locker (MOLLI) for high-resolution T1 mapping in mice using a 3T MRI scanner. MATERIALS AND METHODS To allow high-resolution T1 mapping in mice at high heart rates a multi-shot ECG-triggered 2D MOLLI sequence was developed. In the proposed T1 mapping sequence the optimal number of sampling points and pause cardiac cycles following an initial a...
متن کاملEffect of changes to Modified Look-Locker Inversion (MOLLI) sequence on T1 Mapping at 3.0 Tesla in healthy volunteers
Background Diffuse myocardial fibrosis may be quantified with cardiovascular magnetic resonance (CMR) by calculating extra-cellular volume (ECV) from native and post-contrast T1 values. T1 values are affected by field strength and acquisition sequence. The Modified Look Locker Inversion Recovery (MOLLI) method of T1 mapping is a widely used approach, but many different acquisition schemes have ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2013