An evaluation of the cuffless blood pressure estimation based on pulse transit time technique: a half year study on normotensive subjects.
نویسندگان
چکیده
In the present study, we investigated the relationship between blood pressure (BP) and pulse transit time (PTT) and evaluated the accuracy of the PTT-based cuffless BP estimation on 14 normotensive subjects. Least-squares regression was used to estimate BP in the first test and a repeatability test carried out half year later. BP in the repeatability test was also estimated using the regression coefficients in the first test. The results illustrated that in the first and repeatability tests (1) arterial BP increased and PTT decreased acutely after the exercises and (2) systolic BP was highly correlated with PTT. In the repeatability test, the estimation differences from the references were 0.0 +/- 5.3 mmHg and 0.0 +/- 2.9 mmHg for systolic and diastolic BPs respectively using least-squares regression. However, the estimation differences increased to 1.4 +/- 10.2 mmHg and 2.1 +/- 7.3 mmHg for systolic and diastolic BPs, respectively when the regression coefficients in the first test were used for prediction. In summary, reasonable BP estimations were given in the first and repeatability tests but not using the regression coefficients obtained 6 months ago for some subjects.
منابع مشابه
Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals
Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...
متن کاملContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...
متن کاملA Cuffless Blood Pressure Measurement Based on the Impedance Plethysmography Technique
In the last decade, cuffless blood pressure measurement technology has been widely studied because it could be applied to a wearable apparatus. Electrocardiography (ECG), photo-plethysmography (PPG), and phonocardiography are always used to detect the pulse transit time (PTT) because the changed tendencies of the PTT and blood pressure have a negative relationship. In this study, the PPG signal...
متن کاملImpact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation.
Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation re...
متن کاملتخمین بدون کاف فشارخون مبتنی بر ویژگیهای زمانی سیگنال نبض
Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiovascular engineering
دوره 9 1 شماره
صفحات -
تاریخ انتشار 2009