Low-Intensity Electron Beam Monitoring and Beam Applications at OPU Linac
نویسندگان
چکیده
Low intensity beams are generated with a 18 MeV Sband electron linear accelerator at Osaka Prefecture University. The minimum charge of electrons in a pulsed beam is about several aC. Study has been made to establish the methods for measuring the intensity and the spatial profile of the beam at electron charges of a beam in aC to pC regions. In pC region a beam monitor using a charge-sensitive amplifier and a two dimensional monitor using a scintillator and a CCD camera have been developed. The characteristics of thermoluminescence dosimeters and two-dimensional radiation dosimeters as monitors in fC region have been investigated. From the results it has been found that these dosimeters can be applied to monitoring the low intensity electron beams. Possible beam application researches are discussed.
منابع مشابه
Dental Materials Effect in Neutron Contamination: Electron Mode of a Linac
Background: Neutron contamination is produced in electron beams of linac when tooth or dental materials are located in the path of beam. Objective: This study aims to determine the neutron dose contamination from different dental restoration materials in electron mode of a linac. Material and Methods: In this experimental study, the neutron dose contamination was calculated in the p...
متن کاملAn assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method
Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...
متن کاملInvestigating The Role of Helium Bag On Electron Contamination Removal Using Beam NRC
Introduction: Several studies have discussed to the electron contamination caused by the air column between the head of linac and patient for photon beams. Since it is not possible to measure the electron contamination with practical dosimetry, the Monte Carlo technique is an appropriate and accurate choice to calculate particle flounce in radiation therapy. The purpose of t...
متن کاملTriumf-vecc Electron Linac Beam Dynamics Optimization
The TRIUMF-VECC Electron Linac is a device for gamma-ray induced fission of actinide targets, with applications in nuclear physics and material science. A phased construction and commissioning scheme will eventually lead to a 50 MeV, 10 mA CW linac based on superconducting RF technology. Using this linac to deliver high intensity electron beams for applications such as an energy-recovered light...
متن کاملEnergy Stability in a High Intensity Pulsed SC Proton Linac
Spallation sources dedicated to neutron scattering experiments, as well as multi-purpose facilities serving several applications call for pulsed mode operation of a high intensity proton linac. There is general agreement on the superconducting technology for the high-energy part, which offers some advantages, like higher gradient capabilities or operational costs reduction, as compared to room-...