Correction of vibration artifacts in DTI using phase-encoding reversal (COVIPER)
نویسندگان
چکیده
Diffusion tensor imaging is widely used in research and clinical applications, but still suffers from substantial artifacts. Here, we focus on vibrations induced by strong diffusion gradients in diffusion tensor imaging, causing an echo shift in k-space and consequential signal-loss. We refined the model of vibration-induced echo shifts, showing that asymmetric k-space coverage in widely used Partial Fourier acquisitions results in locally differing signal loss in images acquired with reversed phase encoding direction (blip-up/blip-down). We implemented a correction of vibration artifacts in diffusion tensor imaging using phase-encoding reversal (COVIPER) by combining blip-up and blip-down images, each weighted by a function of its local tensor-fit error. COVIPER was validated against low vibration reference data, resulting in an error reduction of about 72% in fractional anisotropy maps. COVIPER can be combined with other corrections based on phase encoding reversal, providing a comprehensive correction for eddy currents, susceptibility-related distortions and vibration artifact reduction.
منابع مشابه
Hyperelastic Susceptibility Artifact Correction of DTI in SPM
Echo Planar Imaging (EPI) is a MRI acquisition technique that is the backbone of widely used investigation techniques in neuroscience like, e.g., Diffusion Tensor Imaging (DTI). While EPI offers considerable reduction of the acquisition time one major drawback is its high sensitivity to susceptibility artifacts. Susceptibility differences between soft tissue, bone and air cause geometrical dist...
متن کاملb-Matrix Correction Applied to High Resolution DTI
INTRODUCTION – High resolution Diffusion Tensor Imaging (DTI) has been challenging for several reasons. Perhaps the major obstacle is due to the random phase effects that change between successive shots and pixel-by-pixel misregistration caused by patient motion. In addition, DTI images acquired with EPI are typically hampered by geometric distortion, blurring, and – in the case of multi-shot E...
متن کاملPhysiological motion artifact correction in segmented DTI measurement of anesthetized non-human primates
Introduction. Diffusion tensor imaging (DTI) is widely used to study white matter diseases and map fiber tracts in vivo [1]. However DTI is susceptible to any motion during scanning. Segmented EPI, which is often used to achieve higher spatial resolution tensor images for anesthetized non-human primate subjects, is especially vulnerable to inherent physiological motion. Motion results in corrup...
متن کاملReducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملAttenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]
Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...