Combined forced oscillation and forced expiration measurements in mice for the assessment of airway hyperresponsiveness

نویسندگان

  • Karim H Shalaby
  • Leslie G Gold
  • Thomas F Schuessler
  • James G Martin
  • Annette Robichaud
چکیده

BACKGROUND Pulmonary function has been reported in mice using negative pressure-driven forced expiratory manoeuvres (NPFE) and the forced oscillation technique (FOT). However, both techniques have always been studied using separate cohorts of animals or systems. The objective of this study was to obtain NPFE and FOT measurements at baseline and following bronchoconstriction from a single cohort of mice using a combined system in order to assess both techniques through a refined approach. METHODS Groups of allergen- or sham-challenged ovalbumin-sensitized mice that were either vehicle (saline) or drug (dexamethasone 1 mg/kg ip)-treated were studied. Surgically prepared animals were connected to an extended flexiVent system (SCIREQ Inc., Montreal, Canada) permitting NPFE and FOT measurements. Lung function was assessed concomitantly by both techniques at baseline and following doubling concentrations of aerosolized methacholine (MCh; 31.25 - 250 mg/ml). The effect of the NPFE manoeuvre on respiratory mechanics was also studied. RESULTS The expected exaggerated MCh airway response of allergic mice and its inhibition by dexamethasone were detected by both techniques. We observed significant changes in FOT parameters at either the highest (Ers, H) or the two highest (Rrs, RN, G) MCh concentrations. The flow-volume (F-V) curves obtained following NPFE manoeuvres demonstrated similar MCh concentration-dependent changes. A dexamethasone-sensitive decrease in the area under the flow-volume curve at the highest MCh concentration was observed in the allergic mice. Two of the four NPFE parameters calculated from the F-V curves, FEV0.1 and FEF50, also captured the expected changes but only at the highest MCh concentration. Normalization to baseline improved the sensitivity of NPFE parameters at detecting the exaggerated MCh airway response of allergic mice but had minimal impact on FOT responses. Finally, the combination with FOT allowed us to demonstrate that NPFE induced persistent airway closure that was reversible by deep lung inflation. CONCLUSIONS We conclude that FOT and NPFE can be concurrently assessed in the same cohort of animals to determine airway mechanics and expiratory flow limitation during methacholine responses, and that the combination of the two techniques offers a refined control and an improved reproducibility of the NPFE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Forced expiration measurements in mouse models of obstructive and restrictive lung diseases

BACKGROUND Pulmonary function measurements are important when studying respiratory disease models. Both resistance and compliance have been used to assess lung function in mice. Yet, it is not always clear how these parameters relate to forced expiration (FE)-related parameters, most commonly used in humans. We aimed to characterize FE measurements in four well-established mouse models of lung ...

متن کامل

Role of TNFR1 in the innate airway hyperresponsiveness of obese mice.

The purpose of this study was to examine the role of tumor necrosis factor receptor 1 (TNFR1) in the airway hyperresponsiveness characteristic of obese mice. Airway responsiveness to intravenous methacholine was measured using the forced oscillation technique in obese Cpe(fat) mice that were either sufficient or genetically deficient in TNFR1 (Cpe(fat) and Cpe(fat)/TNFR1(-/-) mice) and in lean ...

متن کامل

Forced oscillation techniques for measuring mechanical properties of the respiratory system.

Airway function is usually assessed by tests of forced expiration or, in more specialised laboratories, by measuring airways resistance by whole body plethysmography. Plethysmography depends on the patients' cooperation and requires expensive and bulky apparatus. An alternative non-invasive technique for measuring airflow resistance, using forced oscillation, was introduced by DuBois and collea...

متن کامل

The forced oscillation technique in clinical practice: methodology, recommendations and future developments.

The forced oscillation technique (FOT) is a noninvasive method with which to measure respiratory mechanics. FOT employs small-amplitude pressure oscillations superimposed on the normal breathing and therefore has the advantage over conventional lung function techniques that it does not require the performance of respiratory manoeuvres. The present European Respiratory Society Task Force Report ...

متن کامل

Effect of inhaled beclomethasone dipropionate on isocapnic hyperventilation with cold air in asthmatics, measured with forced oscillation technique.

Isocapnic hyperventilation with cold air (IHCA) is a reliable technique for assessing indirect bronchial hyperresponsiveness in patients with asthma. Impedance measurement of the respiratory system by the forced pseudorandom noise oscillation technique is a sensitive technique to assess changes in bronchial tone after IHCA. The aim of this study was to evaluate the effect of 6 weeks of treatmen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010