2D/3D Registration for Measurement of Implant Alignment After Total Hip Replacement
نویسندگان
چکیده
Measurements of cup alignment after total hip replacement (THR) surgery are typically performed on postoperative pelvic radiographs. Radiographic measurement of cup orientation depends on the position and orientation of the pelvis on the X-ray table, and its variability could introduce significant measurement errors. We have developed a tool to accurately measure 3D implant orientation from postoperative antero-posterior radiographs by registering to preoperative CT scans. The purpose of this study is to experimentally and clinically validate the automatic CT/X-ray matching algorithm by comparing the X-ray based measurements of cup orientation with direct 3D measurements from postoperative CT scans. The mean measurement errors (+/- stdev) found in this study were 0.4 degrees +/-0.8 degrees for abduction and 0.6 degrees +/- 0.8 degrees for version. In addition, radiographic pelvic orientation measurements demonstrated a wide range of inter-subject variability, with pelvic flexion ranging from -5.9 degrees to 11.2 degrees.
منابع مشابه
Determination of the Mechanical Axis of the Femur Using 3d-2d Model to X-ray Registration
For a successful total knee arthroplasty (TKA) and long prosthesis lifespan, correct alignment of the implant components as well as proper soft tissue balancing are of major importance. Studies show that an alignment within +/-3° varus/valgus is correlated with a better outcome (Baethis2004). While conventional planning methods only rely on 2D X-ray images, computer assisted techniques incorpor...
متن کاملA Review of Methods for 2D/3D Registration
2D/3D registration is a special case of medical image registration which is of particular interest to surgeons. Applications of 2D/3D registration are [1] radiotherapy planning and treatment verification, spinal surgery, hip replacement, neurointerventions and aortic stenting. The purpose of this paper is to provide a literature review of the main methods for image registration for the 2D/3D ca...
متن کاملA Review of Methods for 2D/3D Registration
2D/3D registration is a special case of medical image registration which is of particular interest to surgeons. Applications of 2D/3D registration are [1] radiotherapy planning and treatment verification, spinal surgery, hip replacement, neurointerventions and aortic stenting. The purpose of this paper is to provide a literature review of the main methods for image registration for the 2D/3D ca...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملEffect of Segmentation on 3D-to-2D Registration of Implant Models in X-ray Images
In many biomedical applications, it is desirable to estimate the three dimensional (3D) position and orientation (pose) of a metallic rigid object (such as a knee or hip implant) from its projection in a two dimensional (2D) X-ray image. If the geometry of the object is known, as well as the details of the image formation process, then the pose of the object with respect to the sensor can be de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 9 Pt 2 شماره
صفحات -
تاریخ انتشار 2006