Outcomes of excimer laser enhancements in pseudophakic patients with multifocal intraocular lens.

نویسندگان

  • Steven C Schallhorn
  • Jan A Venter
  • David Teenan
  • Julie M Schallhorn
  • Keith A Hettinger
  • Stephen J Hannan
  • Martina Pelouskova
چکیده

PURPOSE The aim of this study was to assess visual and refractive outcomes of laser vision correction (LVC) to correct residual refraction after multifocal intraocular lens (IOL) implantation. PATIENTS AND METHODS In this retrospective study, 782 eyes that underwent LVC to correct unintended ametropia after multifocal IOL implantation were evaluated. Of all multifocal lenses implanted during primary procedure, 98.7% were refractive and 1.3% had a diffractive design. All eyes were treated with VISX STAR S4 IR excimer laser using a convectional ablation profile. Refractive outcomes, visual acuities, patient satisfaction, and quality of life were evaluated at the last available visit. RESULTS The mean time between enhancement and last visit was 6.3±4.4 months. Manifest spherical equivalent changed from -0.02±0.83 D (-3.38 D to +2.25 D) pre-enhancement to 0.00±0.34 D (-1.38 D to +1.25 D) post-enhancement. At the last follow-up, the percentage of eyes within 0.50 D and 1.00 D of emmetropia was 90.4% and 99.5%, respectively. Of all eyes, 74.9% achieved monocular uncorrected distance visual acuity 20/20 or better. The mean corrected distance visual acuity remained the same before (-0.04±0.06 logMAR [logarithm of the minimum angle of resolution]) and after LVC procedure (-0.04±0.07 logMAR; P=0.70). There was a slight improvement in visual phenomena (starburst, halo, glare, ghosting/double vision) following the enhancement. No sight-threatening complications related to LVC occurred in this study. CONCLUSION LVC in pseudophakic patients with multifocal IOL was safe, effective, and predictable in a large cohort of patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

PURPOSE To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. METHODS Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to corr...

متن کامل

Comparison of higher order aberrations and contrast sensitivity after LASIK, Verisyse phakic IOL, and Array multifocal IOL.

PURPOSE To evaluate higher order aberrations and contrast sensitivity after LASIK, implantation of the Verisyse phakic intraocular lens (IOL), and refractive lens exchange with the Array multifocal IOL. METHODS In a prospective, non-randomized case series, LASIK was performed in 20 eyes with the Technolas 217z excimer laser (Bausch & Lomb, Rochester, NY), a Verisyse phakic IOL (AMO Inc, Santa...

متن کامل

Multifocal intraocular lenses and cystoid macular edema: a multicenter study

METHODS: We performed a multicenter (European Eye Institute, Baviera Group), retrospective, comparative study of 10,390 pseudophakic eyes from 5,195 patients who underwent multifocal intraocular lens implantation between January 2009 and January 2012. The exclusion criteria included a history of diabetic retinopathy, ocular trauma, intraocular surgery, vitreous loss during cataract surgery, pre...

متن کامل

Wavefront-guided excimer laser vision correction after multifocal IOL implantation.

PURPOSE To investigate the use of wavefront-guided LASIK after multifocal intraocular lens (IOL) implantation to correct residual ametropia and higher order aberrations. METHODS In a prospective, nonrandomized case series, wavefront-guided LASIK was performed in 27 eyes (19 patients) after multifocal IOL implantation (Tecnis diffractive IOL, n = 20; ReSTOR diffractive IOL, n = 4; ReZoom refra...

متن کامل

Multifocal intraocular lens providing optimized through-focus performance.

A widespread type of multifocal intraocular lens (MIOL) is based on expanding the depth of focus with specific amounts of spherical aberration. However, knowing the optimal wavefront aberration for multifocality does not directly provide a MIOL geometry. To overcome this issue, we present a new strategy to design MIOLs. The method optimizes directly the IOL surface geometries (aspheres with asp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical ophthalmology

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016