Myocardial arterial spin labeling perfusion imaging with improved sensitivity

نویسندگان

  • Hung Phi Do
  • Terrence R Jao
  • Krishna S Nayak
چکیده

BACKGROUND Myocardial arterial spin labeling (ASL) is a noninvasive MRI based technique that is capable of measuring myocardial blood flow (MBF) in humans. It suffers from poor sensitivity to MBF due to high physiological noise (PN). This study aims to determine if the sensitivity of myocardial ASL to MBF can be improved by reducing image acquisition time, via parallel imaging. METHODS Myocardial ASL scans were performed in 7 healthy subjects at rest using flow-sensitive alternating inversion recovery (FAIR) tagging and balanced steady state free precession (SSFP) imaging. Sensitivity encoding (SENSE) with a reduction factor of 2 was used to shorten each image acquisition from roughly 300 ms per heartbeat to roughly 150 ms per heartbeat. A paired Student's t-test was performed to compare measurements of myocardial blood flow (MBF) and physiological noise (PN) from the reference and accelerated methods. RESULTS The measured PN (mean ± standard deviation) was 0.20 ± 0.08 ml/g/min for the reference method and 0.08 ± 0.05 ml/g/min for the accelerated method, corresponding to a 60% reduction. PN measured from the accelerated method was found to be significantly lower than that of the reference method (p=0.0059). There was no significant difference between MBF measured from the accelerated and reference ASL methods (p=0.7297). CONCLUSIONS In this study, significant PN reduction was achieved by shortening the acquisition window using parallel imaging with no significant impact on the measured MBF. This indicates an improvement in sensitivity to MBF and may also enable the imaging of subjects with higher heart rates and imaging during systole.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial ASL-CMR perfusion imaging with improved sensitivity using GRAPPA

Background Myocardial arterial spin labeling (ASL) is a non-contrast CMR technique for measuring myocardial blood flow (MBF), but has relatively low signal-to-physiological noise (PN). Therefore perfusion measurements are made over several averaged pixels within left ventricular (LV) segments and not individual pixels. Shorter image acquisition times using SENSE parallel imaging has been shown ...

متن کامل

Qualitative and quantitative myocardial perfusion with arterial spin labeling

Introduction A reduction of myocardial blood perfusion is the main physio-pathologic mechanism determining ischemic heart disease. Whilst SPECT and echocardiography are considered the reference standards for imaging perfusion defects, MRI techniques are emerging. Dynamic imaging of the first-pass of a contrast agent is currently the most frequently used of these techniques, however, guidelines ...

متن کامل

Arterial spin labeling CMR perfusion imaging is capable of continuously monitoring myocardial blood flow during stress

Background Myocardial arterial spin labeling (ASL) is a non-invasive non-contrast CMR perfusion imaging technique [Zun et al., ‘09] that is compatible with adenosine stress testing [Zun et al., ‘11]. Here, we demonstrate its ability to continuously monitor MBF during stress, which has a variety of potential applications including interventional CMR and the study of endothelial function. We used...

متن کامل

Reduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla.

Arterial spin labeling (ASL) perfusion contrast is not based on susceptibility effects and can therefore be used to study brain function in regions of high static inhomogeneity. As a proof of concept, single-shot spin-echo echo-planar imaging (EPI) acquisition was carried out with a multislice continuous ASL (CASL) method at 1.5T. A bilateral finger tapping paradigm was used in the presence of ...

متن کامل

Cine-ASL: a new arterial spin labeling method for myocardial perfusion mapping in mice using a Cine-FLASH labeling and readout module

This study presents a novel arterial spin labeling method to assess myocardial perfusion in small rodents. An ECG-gated pseudo-continuous labeling approach is combined with simultaneous readout over the cardiac cycle using Cine-FLASH. This method allows shorter acquisition times than the previously used Look-Locker FAIR gradient-echo technique while preserving spatial resolution and robustness ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014