Intraductal micro magnetic resonance imaging and spectroscopy

نویسندگان

  • D Strick
  • M Cohen
  • WG Clark
  • D Mills
  • A Chu
  • J Judy
چکیده

The majority of breast cancers originate in the mammary ducts. As such many diagnostic techniques introduce mmdiameter devices into the ducts through the nipple. Established intraductal techniques include ductal lavage, and white-light or fluorescence endoscopy. While reported values vary, these techniques typically suffer from low sensitivity and specificity. Similarly, Magnetic Resonance Imaging (MRI) for breast oncology suffers a high rate of false positives. Magnetic resonance (MR) spectroscopy is highly effective in distinguishing between benign and malignant tissue. However, clinical relevance is limited to late-stage of disease due to a required cubic-centimeter volume for diagnosis. Small-volume sensitivity for spectroscopy and imaging is possible through use of a miniature radio-frequency (RF) coil. An intraductal RF microcoil reduces the required volume of diseased tissue to a cubic-millimeter, bringing spectroscopy to early stages of early diagnosis. Micro-scale images from an intraductal microcoil may enable high-precision localization of tumors and tumor margins. The microcoil catheter was designed with an approximate diameter of 1 mm for intraductal use and for possible integration with ductoscopes. Experimental verification of the first-generation coil-design was achieved through ex vivo MR imaging of tissue. As expected, the microcoil provided microscale images. While 3-T (128 MHz) MRI typically provides 1 to 30 voxels per-cubic-mm the MRI microcoil can provide hundreds, and even thousands of voxels in the same volume. The first generation microcoil consisted of a 1-mmdiameter solenoid with 4.5 turns, spaced 0.05 mm apart, leading to 25-mm long parallel leads, with one of the leads passing through the center of the solenoid. A crucial requirement for optimal MR coil design is a homogenous magnetic field generated in the coil. Unfortunately, the central conductor inside the solenoid of the original microcoil greatly disturbed the homogeneity of the magnetic-field. The parallel-leads of the first generation device correspond to a popular catheter-coil geometry, a singleloop coil. The parallel leads therefore collect unwanted signal, in other words noise. The new design overcomes both of these flaws. Turn-spacing of the first microcoil design was intended for optimizing the signal collected from the center of the solenoid. However, since the target tissue is at the tip of the solenoid, the new design is optimized for our target tissue with ten turns separated by the thin insulation of the wire. The turn-spacing of the first generation microcoil was controlled by a thick layer of insulation that also provided a good barrier from the body. Due to the lack of a thick insulator, the second generation-design required a new configuration for isolating the coil from the body to prevent degradation of the performance over time. We analyzed the stability of the new microcoils by soaking 5 microcoils in body temperature saline and measuring the impedance at 128 MHz over time. The impedance of the microcoils remained constant for nearly 2 hours, and increased only slightly after 4 hours. Preliminary heating experiments indicate that little to no heating occurs during use of the microcoil as an MR transceiver. Initial imaging results confirm that the second generation microcoil improves greatly on the first generafrom 6th International Symposium on the Intraductal Approach to Breast Cancer Santa Monica, CA, USA. 19–21 February 2009

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Glioblastoma Multiforme Tumor in Magnetic Resonance Spectroscopy Based on Support Vector Machine

Introduction: The brain tumor is an abnormal growth of tissue in the brain, which is one of the most important challenges in neurology. Brain tumors have different types. Some brain tumors are benign and some brain tumors are cancerous and malignant. Glioblastoma Multiforme (GBM) is the most common and deadliest malignant brain tumor in adults. The average survival rate for peo...

متن کامل

Fe3O4@Ag Nanoprobe for Detection of Ovarian Cancer Cell Line Using Magnetic Resonance Imaging

Background and Aims: Magnetic resonance imaging (MRI) plays an essential role in molecular imaging by delivering the contrast agent into targeted cells. The aim of this study was to evaluate the use of magnetic nanoparticles containing iron oxide and silver (Fe3O4@Ag core-shell nanoprobe) as a contrast agent for the detection of ovarian cancer cell line ovcar-3. Materials and Methods: Co-preci...

متن کامل

MR Spectroscopy and Diffusion Weighted Imaging Findings of Primary Non-Hodgkin Lymphoma of the Breast: Two Case Reports

Primary non-Hodgkin lymphoma (NHL) of the breast is a rare clinical entity, representing about 0.40.5% of all breast malignancies and 1.7-2.2% of all extranodal NHL (1-3). We describe two cases of primary breast lymphomas in a middle aged woman and discuss characteristics of classical findings of classical magnetic resonance (MR) imaging, MR spectroscopy and diffusion weighted (DW) imaging as w...

متن کامل

Use of Magnetic Resonance Imaging in Food Quality Control: A Review

Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...

متن کامل

Study of Coincidence of Hoffa’s Fat Pad Associated Injuries in Knee Traumas in Magnetic Resonance Imaging

Background and Objective: Hoffa’s fat pad injuries are often caused by acute direct and indirect trauma and chronic recurrent micro-trauma, and its disorders are associated with other traumas and injuries that have been less paid attention to in radiological studies. Therefore, this study was performed to evaluate the injuries associated with Hoffa’s fat pad injury in knee trauma using the diag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Proceedings

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009