A purge and trap integrated microGC platform for chemical identification in aqueous samples.

نویسندگان

  • Muhammad Akbar
  • Shree Narayanan
  • Michael Restaino
  • Masoud Agah
چکیده

The majority of current micro-scale gas chromatography (μGC) systems focus on air sampling to detect volatile organic compounds (VOCs). However, purging the VOCs from a water sample using microsystems is an unchartered territory. Various organic compounds used in everyday life find their way to water bodies. Some of these water organic compounds (WOCs) persist or degrade slowly, threatening not just human existence but also aquatic life. This article reports the first micro-purge extractor (μPE) chip and its integration with a micro-scale gas chromatography (μGC) system for the extraction and analysis of water organic compounds (WOCs) from aqueous samples. The 2 cm × 3 cm μPE chip contains two inlet and outlet ports and an etched cavity sealed with a Pyrex cover. The aqueous sample is introduced from the top inlet port while a pure inert gas is supplied from the side inlet to purge WOCs from the μPE chip. The outlets are assigned for draining water from the chip and for directing purged WOCs to the micro-thermal preconcentrator (μTPC). The trapped compounds are desorbed from the μTPC by resistive heating using the on-chip heater and temperature sensor, are separated by a 2 m long, 80 μm wide, and 250 μm deep polydimethylsiloxane (OV-1) coated μGC separation column, and are identified using a micro-thermal conductivity detector (μTCD) monolithically integrated with the column. Our experiments indicate that the combined system is capable of providing rapid chromatographic separation (<1.5 min) for quaternary WOCs namely toluene, tetrachloroethylene (PCE), chlorobenzene and ethylbenzene with a minimum detection concentration of 500 parts-per-billion (ppb) in aqueous samples. The proposed method is a promising development towards the future realization of a miniaturized system for sensitive, on-site and real-time field analysis of organic contaminants in water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Techniques for Optimizing the Analysis of Volatile Organic Compounds in Water Using Purge-and-Trap/GC/MS Application

The analysis of volatile organic compounds in water is normally accomplished by purge-and-trap/gas chromatography/mass spectrometry. U.S. EPA Method 8260B with purge and trap sample introduction is widely used for the analysis of aqueous samples other than drinking water. This application note discusses problems that can arise and some easy solutions for them. These techniques have resulted in ...

متن کامل

Simultaneous speciation of monomethylmercury and monoethylmercury by aqueous phenylation and purge-and-trap preconcentration followed by atomic spectrometry detection.

A new method for the detection of trace levels of organomercury species has been developed by combining the high enrichment capacity of purge and trap with aqueous phenylation derivatization. Phenylation products of monomethylmercury (MeHg) and monoethylmercury (EtHg) were first separated by capillary gas chromatography and then detected by atomic fluorescence spectrometry (AFS) or inductively ...

متن کامل

Benefits and Limitations of Static Headspace and Purge-and-Trap for the Analysis of VOCs

Static headspace analysis can provide reasonably good sensitivity for halogenated hydrocarbons and aromatic compounds. But USEPA Method 524.2 Revision 4 requires the evaluation of several analytes containing different functional groups such as ketones, ethers, and esters. Such compounds can be particularly difficult to analyze at low concentration using static headspace due to the affinity of p...

متن کامل

Identification of Aroma Compounds of Lamiaceae Species in Turkey Using the Purge and Trap Technique

The present research was planned to characterize the aroma composition of important members of the Lamiaceae family such as Salvia officinalis, Lavandula angustifolia and Mentha asiatica. Aroma components of the S. officinalis, L. angustifolia and M. asiatica were extracted with the purge and trap technique with dichloromethane and analyzed with the gas chromatography-mass spectrometry (GC-MS) ...

متن کامل

Analysis of human skin emanations by gas chromatography/mass spectrometry. 1. Thermal desorption of attractants for the yellow fever mosquito (Aedes aegypti) from handled glass beads.

Handled glass has the ability to collect and concentrate nonaqueous human skin emanations while minimizing the collection of aqueous perspiration. Compounds originating from the skin and collected on glass have previously been found to attract the Aedes aegypti species of mosquito. Therefore, glass beads were used as the medium to collect skin emanations from humans for subsequent chemical anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 139 13  شماره 

صفحات  -

تاریخ انتشار 2014