Markerless Roentgen Stereophotogrammetric Analysis for in vivo implant migration measurement using three dimensional surface models to represent bone.
نویسندگان
چکیده
Recent studies have shown that model-based RSA using implant surface models to detect in vivo migration is as accurate as the classical marker-based RSA method. Use of bone surface models would be a further advancement of the model-based method by decreasing complications arising from marker insertion. The aim of this pilot investigation was to assess the feasibility of a "completely markerless" model-based RSA in detecting migration of an implant using bone surface models instead of bone markers. A total knee arthroplasty (TKA) was performed on a human cadaver knee, which was subsequently investigated by repeated RSA measurements performed by one observer. The cadaver knee was CT scanned prior to implantation of the TKA. Tibia-fibular surface models were created using two different commercially available software packages to investigate the effect of segmentation software on the accuracy of repeated migration measures of zero displacement by one observer. Reverse engineered surface models of the TKA tibial component were created. The analysis of the RSA images was repeated 10 times by one individual observer. For the markerless method, the greatest apparent migration observed about the three anatomical axes investigated was between -2.08 and 1.35 mm (SD ≤ 0.88) for z-axis translation, and -4.57° to 7.86° (SD ≤ 3.17) for R(y)-axis rotation, which were well beyond out of the range of what is typically considered adequate for clinically relevant RSA measurements. Use of tibia-fibular surface models of the bone instead of markers could provide practical advantages in evaluating implant migration. However, we found the accuracy and precision of the markerless approach to be lower than that of marker-based RSA, to a degree which precludes the use of this method for measuring implant migration in its present form.
منابع مشابه
Dependence of model-based RSA accuracy on higher and lower implant surface model quality
BACKGROUND Model-based Roentgen Stereophotogrammetric Analysis (MBRSA) allows the accurate in vivo measurement of the relative motion between an implant and the surrounding bone (migration), using pose-estimation algorithms and three dimensional geometric surface models of the implant. The goal of this study was thus to investigate the effect of surface model resolution on the accuracy of the M...
متن کاملCement migration after THR. A comparison of charnley elite and exeter femoral stems using RSA.
Studies using roentgen stereophotogrammetric analysis (RSA) have shown that the femoral components of cemented total hip replacements (THR) migrate distally relative to the bone, but it is not clear whether this occurs at the cement-implant or the cement-bone interface or within the cement mantle. Our aim was to determine where this migration occurred, since this has important implications for ...
متن کاملEffect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis
Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...
متن کاملEffect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis
Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...
متن کاملRoentgen stereophotogrammetric analysis of the Birmingham hip resurfacing arthroplasty. A two-year study.
The Birmingham hip resurfacing (BHR) arthroplasty is a metal-on-metal prosthesis for which no medium- or long-term results have been published. Despite this, it is increasing in popularity as an alternative to stemmed prostheses for younger patients. Since the fixation of the socket is conventional, the major concern is long-term failure of the femoral component. This can be predicted by the us...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanics
دوره 45 8 شماره
صفحات -
تاریخ انتشار 2012