MRI Evidence of Endolymphatic Impermeability to the Gadolinium Molecule in the In Vivo Mouse Inner Ear at 9.4 Tesla

نویسندگان

  • S Allen Counter
  • Sahar Nikkhou
  • Stefan Brené
  • Peter Damberg
  • Adam Sierakowiak
  • Tomas Klason
  • Cecilia Engmér Berglin
  • Göran Laurell
چکیده

OBJECTIVE Previous in vivo experimental magnetic resonance imaging (MRI) investigations of the mammalian inner ear at 4.7 Tesla have indicated that intravenously injected gadolinium (Gd) penetrates the perilymphatic labyrinth, but not the endolymphatic membranous labyrinth. In the present study, high field MRI at 9.4T was used to visualize the in vivo mouse vestibulo-cochlea system, and to determine whether the endolymphatic system is permeable to a Gd complex. METHODS A 9.4 T Varian magnet equipped with a 12 cm inner diameter gradient system with maximum gradient strength of 600 mT/m, a millipede coil (Varian design) and a Gd contrast agent were used for image acquisition in the normal C57 BL-6 mouse. RESULTS High-resolution 2D and 3D images of the mouse cochlea were acquired within 80 minutes following intravenous injection of Gd. Gd initially permeated the perilymphatic scala tympani and scala vestibuli, and permitted visualization of both cochlear turns from base to apex. The superior, inferior and lateral semicircular canals were subsequently visualized in 3 planes. The membranous endolymphatic labyrinth was impermeable to intravenously injected Gd, and thus showed no apparent uptake of Gd at 9.4T. CONCLUSION The 9.4T field strength MRI permitted acquisition of high resolution images of anatomical and physiological features of the normal, wild type mouse perilymphatic inner ear in vivo, and provided further evidence that the endolymphatic system is impermeable to intravenously injected Gd.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vasopressin induces endolymphatic hydrops in mouse inner ear, as evaluated with repeated 9.4 T MRI.

From histopathological specimens, endolymphatic hydrops has been demonstrated in association with inner ear disorders. Recent studies have observed findings suggestive of hydrops using MRI in humans. Previous studies suggest that vasopressin may play a critical role in endolymph homeostasis and may be involved in the development of Ménière's disease. In this study we evaluate the effect of vaso...

متن کامل

CASE REPORT Secondary Endolymphatic Hydrops Following Sudden Deafness Detected by MRI after Intratympanic Administration of Gadolinium

the hydrops by image analyses. A 64 years-old female who showed partial recovery of hearing disturbance two months after the onset of sudden deafness underwent inner ear MRI in combination with intratympanic injection of gadolinium. Two-dimensional fluid-attenuated inversion recovery (2D-FLAIR) sequences taken by 3 tesla MR unit showed endolymphatic hydrops in the cochlea. Electrocochleogram co...

متن کامل

Experimental Fusion of Contrast Enhanced High-Field Magnetic Resonance Imaging and High-Resolution Micro-Computed Tomography in Imaging the Mouse Inner Ear

OBJECTIVE Imaging cochlear, vestibular, and 8th cranial nerve abnormalities remains a challenge. In this study, the membranous and osseous labyrinths of the wild type mouse inner ear were examined using volumetric data from ultra high-field magnetic resonance imaging (MRI) with gadolinium contrast at 9.4 Tesla and high-resolution micro-computed tomography (µCT) to visualize the scalae and vesti...

متن کامل

Endolymphatic Hydrops Detected by 3-Dimensional Fluid-Attenuated Inversion Recovery MRI following Intratympanic Injection of Gadolinium in the Asymptomatic Contralateral Ears of Patients with Unilateral Ménière’s Disease

BACKGROUND The aim of this study was to identify the incidence of endolymphatic hydrops using 3-dimensional fluid-attenuated inversion recovery (3D-FLAIR) magnetic resonance imaging (MRI) in the contralateral ear in patients with unilateral Ménière's disease (MD). MATERIAL AND METHODS This was a prospective study. 3D-FLAIR MRI was performed with a 3 Tesla (3 T) unit 24 h after the intratympan...

متن کامل

Semi-Quantitative vs. Volumetric Determination of Endolymphatic Space in Menière’s Disease Using Endolymphatic Hydrops 3T-HR-MRI after Intravenous Gadolinium Injection

Magnetic resonance imaging enhances the clinical diagnosis of Menière's disease. This is accomplished by in vivo detection of endolymphatic hydrops, which are graded using different semi-quantitative grading systems. We evaluated an established, semi-quantitative endolymphatic hydrops score and with a quantitative method for volumetric assessment of the endolymphatic size. 11 patients with Meni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013