A New Device for Percutaneous Elevation of the Depressed Fractures of Tibial Condyles
نویسندگان
چکیده
INTRODUCTION Monocondylar tibia plateau fractures with non-comminuted fragments can be treated using percutaneous screws. Currently indirect methods of reduction are used and thus the technique is limited to fragments with less than 5 mm depression. The first author has designed a device for direct elevation and reduction of the fragments thus potentially expanding the indications of percutaneous screws to fragments with >5mm depression. TECHNICAL NOTE A total of ten cases were treated by this method of percutaneous elevation of the depressed fractures of lateral condyles of the Tibia using this device. Device was inserted through a bony window on the anteromedial surface of tibia. The inner piston of the device in slowly hammered inside thus elevating the depressed fragment. Elevation of fragment could be achieved in all the cases. The fractures were fixed with cancellous screws applied percutaneously. There were no cases with loss of fixation or subsidence of the fragment. All cases achieved radiological union and have good knee function at follow up. CONCLUSION The new device is able to elevate unicondylar tibia plateau fragments with no subsidence or loss of fixation in our series. A longer follow up in a larger sample will be needed to establish the technique.
منابع مشابه
A New Device for Percutaneous Elevation of the Depressed Fractures of Tibial Condyles- A Response
1. Most of Schatzker Type II and Type III tibial plateau fractures are seen in osteoporotic bones in older age and are comminuted most of the times which have been excluded from your study. 2. The diameter of the solid inner piston is 10 mm may not be sufficient to elevate comminuted fragments. 3. Why not use bone graft to support elevated bone fragments because we are not sure if the screw can...
متن کاملA New Device for Percutaneous Elevation of the Depressed Fractures of Tibial Condyles- Authors’ Reply
1. Most of Schatzker Type II and Type III tibial plateau fractures are seen in osteoporotic bones in older age and are comminuted most of the times which have been excluded from your study. 2. The diameter of the solid inner piston is 10 mm may not be sufficient to elevate comminuted fragments. 3. Why not use bone graft to support elevated bone fragments because we are not sure if the screw can...
متن کاملPercutaneous inflation osteoplasty for indirect reduction of depressed tibial plateau fractures.
Anatomic reduction of articular depression tibial plateau fractures is challenging. The authors describe a new technique using percutaneous balloon-guided inflation osteoplasty for a depressed lateral tibial plateau fracture. The fluoroscopy-guided inflation osteoplasty restores the joint surface anatomically in a minimally invasive fashion. The metaphyseal void is filled with a fast-setting fl...
متن کاملOutcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia
Background: Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...
متن کاملTreatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?
Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...
متن کامل