Implantable cardioverter defibrillator with and without defibrillation threshold testing.
نویسندگان
چکیده
BACKGROUND Defibrillation threshold (DFT) testing at the time of implantable cardioverter defibrillator (ICD) insertion is performed routinely. This practice is being reconsidered due to doubts about its ability to improve ICD efficacy and evidence that survival may not be affected by the test. OBJECTIVES To compare the outcome of ICD recipients who underwent DFT testing and those who did not. METHODS A total of 213 eligible patients were implanted with an ICD between 2004 and 2009. DFT testing was performed in 80 of them. We compared total mortality, appropriate and inappropriate ICD shocks, and anti-tachycardia pacing (ATP) events between DFT and non-DFT patients during a follow-up of 2 years. RESULTS On comparing the DFT and non-DFT groups, we found a 2 year mortality rate of 7.5% versus 8.3%, respectively (P = 0.8). Furthermore, 20.7% of patients in the DFT group and 12.4% in the non-DFT group had at least one episode of ICD shock (P = 0.15). With regard to ICD treatment (ICD shocks or ATP events), 57.7% in the DFT group and 64.2% in the non-DFT group received appropriate treatments (P = 0.78). CONCLUSIONS No significant differences in the incidence of 2 year mortality or percentage of ICD treatment emerged between the DFT and non-DFT groups.
منابع مشابه
Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).
BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...
متن کاملAzygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement
Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.
متن کاملVentricular tachycardia initiated by high energy cardioversion in a patient with an implantable cardioverter defibrillator.
A transvenous implantable cardioverter defibrillator (ICD) was implanted into a 58 year old woman with idiopathic dilated cardiomyopathy who had drug refractory monomorphic ventricular tachycardia (VT). Antitachycardia pacing failed to terminate the VT; termination was attempted at 24 J, which was above the defibrillation threshold. When cardioversion at 24 J was delivered, VT with a different ...
متن کاملRoutine tests should be challenged in cardiology.
The need for routine diagnostic tests and procedures needs to be challenged in medical practice, because of continuous pressure to reduce the costs of health care systems. If costs can be minimized by avoidance of routine tests, more sources can perhaps be directed to new advanced diagnostic and therapeutic procedures. This challenge is important particularly in cardiology, because while new di...
متن کاملComparison of outcomes in patients undergoing defibrillation threshold testing at the time of implantable cardioverter-defibrillator implantation versus no defibrillation threshold testing.
BACKGROUND Inability to perform defibrillation threshold (DFT) testing during implantable cardioverter defibrillator (ICD) implantation due to co-morbidities may influence long-term survival. METHODS Retrospective review at The University of Michigan (1999-2004) identified 55 patients undergoing ICD implantation without DFT testing ("No-DFT group"). A randomly selected sample of patients (n =...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Israel Medical Association journal : IMAJ
دوره 14 6 شماره
صفحات -
تاریخ انتشار 2012