Adaptation of the EMIT serum digoxin assay to a mini-disc centrifugal analyzer.

نویسندگان

  • S D Brunk
  • H V Malmstadt
چکیده

We have modified the EMIT (Syva) serum digoxin assay for use with a mini-disc centrifugal analyzer. A minicomputer is used to control data acquisition, calculations, and readout for 14 cuvettes simultaneously. Thus, it is not necessary for time each individual assay manually or to plot calibration curves on graph paper. We use incubation times and dilutions similar to those used for the manual procedure, but we have changed the buffer solution, decreased the measurment time, and decreased the required serum volume per assay fivefold. We evaluated day-to-day and within-run precision, using Syva calibrators and control sera. EMIT assay values for radioimmunoassay control sera correlate well with the supplier's stated values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enzyme immunoassay and enzyme inhibition assay of methotrexate, with use of the centrifugal analyzer.

Methotrexate was determined by the homogeneous enzyme immunoassay (EMIT) with the Multistat and CentrifiChem centrifugal analyzers and by the enzyme inhibition assay with use of the Multistat centrifugal analyzer. With both methods, the standard curve extends from 0.2 to 2.0 mumol/L and there is no interference from bilirubin in concentrations up to 100 mg/L. Moderately lipemic samples do not i...

متن کامل

Adaptation of "EMIT" technique for serum phenobarbital and diphenylhydantoin assays to the miniature centrifugal analyzer.

We used a miniature centrifugal analyzer in a spectrophotometric rate-measurement mode to determine the anticonvulsant drugs phenobarbital and diphenylhydantoin in serum, by use of a modified enzyme immunoassay ("EMIT", Syva Corp.) We decreased reagent cost per determination by at least sixfold by means of microscale techniques. Also, the analysis rate is increased by measuring multiple samples...

متن کامل

Evaluation of enzyme-multiplied immunoassay technique (EMIT) for determination of serum digoxin.

Sixty-seven digoxin-containing sera were analyzed by both radioimmunoassay and EMIT. After some important modifications of the EMIT method, agreement between the two methods was very good. Reproducibility of the EMIT assay was excellent; daily variations in values found for control sera were quite small, and recovery of added digoxin was good. Slight hemolysis hadnegligible effects, but highly ...

متن کامل

Adaptation of EMIT drug assays to a random-access automated clinical analyzer.

Enzyme multiplied immunoassay technique (EMIT) assays for theophylline, carbamazepine, phenytoin, phenobarbital, valproic acid, acetaminophen, gentamicin and tobramycin, have been adapted to the Technicon RA-1000 random access analyzer. Working reagents are stable for a period of at least one week, and calibration need only be performed when preparing fresh reagents. Between-day precision range...

متن کامل

Enzyme immunoassays with the miniature centrifugal fast analyzer.

We studied the EMIT (Enzyme Multiplied Immunoassay Technique, Syva) procedures for the assay of phenytoin and phenobarbital in serum, adapting them to the miniature Centrifugal Fast Analyzer. For different concentrations of drug, each rate of reaction decreased continuously with time, tending to converge on a single common value. The rate was most affected by the concentration of drug almost im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 1977