Transvenous cardioversion for the management of recurrent ventricular arrhythmias.
نویسندگان
چکیده
The efficacy of transvenous cardioversion and defibrillation for treating life threatening spontaneous ventricular arrhythmias was assessed in a study of 17 patients in a cardiac care unit. Eleven had ventricular tachycardia, five had ventricular fibrillation, and one had both. Transvenous cardioversion successfully terminated tachyarrhythmias on 42 separate occasions in ten patients. Stable electrode positions could not be achieved in two patients, recurrent late displacement occurred in one, and four patients had no further arrhythmias requiring cardioversion once the lead was placed. The energy levels required for successful cardioversion ranged from 0.05 J to 25 J for ventricular tachycardia and from 1 J to 25 J for ventricular fibrillation. The nine successful shocks of 1 J or less did not require sedation or general anaesthesia. High energy (25 J) endocardial shocks were unsuccessful in terminating arrhythmias in two patients, one with ventricular tachycardia and the other with both ventricular tachycardia and fibrillation. Minor unwanted effects of endocardial shocks occurred in five patients. These were acceleration of ventricular tachycardia in two patients and complications of pacing via the special lead in three others: failure of sensing occurred in all three and one patient also had a transient rise in pacing threshold. A postmortem examination in one patient who had received three unsuccessful high energy shocks revealed localised endocardial necrosis at the site of the distal electrode. Transvenous cardioversion offers advantages over external cardioversion but at present practical difficulties limit its application to patients with recurrent ventricular arrhythmias that cannot readily be controlled by conventional methods.
منابع مشابه
Comparative effcacy of transvenous cardioversion and pacing in patients with sustained ventricular tachycardia : a prospective , randomized , crossover study
We performed a prospective, randomized crossover study to evaluate the comparative efficacy of transvenous cardioversion and rapid ventricular pacing for termination of induced ventricular tachycardia in patients with spontaneous ventricular tachycardia and organic heart disease. Sixtytwo episodes of ventricular tachycardia were induced in 15 patients, mean age 60 + 10 years, during electrophys...
متن کامل2-D ECHO DIAGNOSIS OF PULMONARY ARTERY TUMOR/Wright
4. Zipes DP, Jackman WM, Heger JJ, Chilson DA, Browne KF, Naccarelli GV, Rahilly GT Jr, Prystowsky EN: Clinical transvenous cardioversion of recurrent life-threatening ventricular tachyarrhythmias: low energy synchronized cardioversion of ventricular tachycardia and termination of ventricular fibrillation in patients using a catheter electrode. Am Heart J 103: 789, 1982 5. Wellens HJJ, Lie KI, ...
متن کاملComparative efficacy of transvenous cardioversion and pacing in patients with sustained ventricular tachycardia: a prospective, randomized, crossover study.
We performed a prospective, randomized crossover study to evaluate the comparative efficacy of transvenous cardioversion and rapid ventricular pacing for termination of induced ventricular tachycardia in patients with spontaneous ventricular tachycardia and organic heart disease. Sixty-two episodes of ventricular tachycardia were induced in 15 patients, mean age 60 +/- 10 years, during electrop...
متن کاملEarly Experience with the Subcutaneous ICD
The Subcutaneous Internal Cardiac Defibrillator (S-ICD) represents a major advance in the care of patients who have an indication for an internal cardiac defibrillator without pacing indications. Its main advantage is that it can deliver a shock to cardiovert ventricular arrhythmias utilising a tunnelled subcutaneous lead, negating the risks associated with conventional transvenous systems. Ini...
متن کاملA simplified, single-lead unipolar transvenous cardioversion-defibrillation system.
BACKGROUND Transvenous implantable cardioverter-defibrillators provide significant advantages in the treatment of patients with life-threatening ventricular arrhythmias. However, present technology requires considerable electrophysiology expertise, multiple incisions, and long operative times for successful implementation. METHODS AND RESULTS In this study, we present a prototype of a new, ea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 58 3 شماره
صفحات -
تاریخ انتشار 1987