[Medium term results of unipolar modular radial head arthroplasty].
نویسندگان
چکیده
OBJECTIVE Analyze the results of unipolar modular radial head arthroplasty in the treatment of complex fractures associated with elbow joint instability. MATERIAL AND METHOD Retrospective design study of 44 patients, 17 men and 27 women with a mean age of 51 years (17-78) who suffered radial head fractures (Mason III) in the context of an unstable elbow injury. Mean follow-up was 21.2 months (12-60). Radial head replacement was performed with a unipolar modular prosthesis with a fixed stem (Ascension(®) Modular Radial Head [MRH]), associating repair of concomitant lesions. The Mayo scale Elbow Performance Score (MEPS) was used to perform the functional assessment. A radiological evaluation was performed at the last follow-up and the complications were recorded. RESULTS Final arc of flexion-extension was 108° with an average of 135° of prono-Supination. At final follow-up, 82% of results were satisfactory according to the MEPS. The 40% of patients (17) had radiographic signs of lucencies around the stem, although most of them were asymptomatic. Two of them needed a second surgical procedure because of painful prosthetic loosening and further surgery was required for a prosthesis dislocation. DISCUSSION Radial head implants are an adequate treatment option for restoring stability in complex radial head fractures. Modularity allows a wide range of size combination and helps to avoid overstuffing. Periprosthetic osteolysis could be associated with the presence of pain, so it is necessary to perform long-term studies to test the potential complications of this finding.
منابع مشابه
Long-term Outcomes after Primary Radial Head Resection Arthroplasty vs. Acute Radial Head Resection vs. Secondary Prosthetic Removal in Comminuted Radial Head Fractures
Background: Aim of this study was to compare the clinical and radiological long-term outcomes following operativetreatment of comminuted radial head fractures using 1) primary radial head resection arthroplasty, 2) acute radial headresection, or 3) necessary secondary prosthetic removal. Additionally, we evaluated complex radial head fracturescombined with elbow dislocation and verified the hyp...
متن کاملRadiographic Predictors for Short-term Functional Outcome after Radial Head Arthroplasty in Patients with Persistent Symptoms after Treatment for Radial Head
Background: Evaluation of the accurate position after radial head arthroplasty remains a challenge for surgeons.Standard radiographs are used to evaluate the position of the implant, however, results regarding radiographicdeficiencies on clinical outcome are not consistent. In this retrospective study our main aim was to determine if subtleradiographic deficiencies after radia...
متن کاملFailure of a Unipolar Radial Head Prosthesis Due to Component Dissociation.
Radial head implant arthroplasty is a consideration for the treatment of comminuted, unreconstructable fractures of the radial head. Many prosthetic designs exist and can be unipolar or bipolar, each of which can be cemented or noncemented. For most unipolar designs, a prosthetic stem is first implanted into the proximal radius. The prosthetic radial head is then impacted onto a morse taper on ...
متن کاملShort- to medium-term outcomes of radial head replacement arthroplasty in posttraumatic unstable elbows: 20 to 70 months follow-up.
BACKGROUND The radial head is considered the main stabilizer of the elbow when the medial collateral ligament and lateral ulnar collateral ligament have been compromised. Radial head replacement (RHR) is indicated for patients with irreparable or non-united radial head fractures associated with elbow stiffness or instability. The present study aimed to analyze the clinical results after treatme...
متن کاملRadial Head Fractures Treated with Modular Metallic Radial Head Replacement: Outcomes at a Mean Follow-up of Eight Years.
BACKGROUND Radial head arthroplasty is commonly used to treat acute unreconstructible radial head fractures. The purpose of this study was to report on the clinical and radiographic outcomes at a minimum follow-up of five years after radial head arthroplasty with a modular metallic implant for the treatment of acute radial head fractures. METHODS The cases of fifty-five patients with unrecons...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de cirugia ortopedica y traumatologia
دوره 57 3 شماره
صفحات -
تاریخ انتشار 2013