VO2 and VCO2 variabilities through indirect calorimetry instrumentation
نویسندگان
چکیده
The aim of this paper is to understand how to measure the VO2 and VCO2 variabilities in indirect calorimetry (IC) since we believe they can explain the high variation in the resting energy expenditure (REE) estimation. We propose that variabilities should be separately measured from the VO2 and VCO2 averages to understand technological differences among metabolic monitors when they estimate the REE. To prove this hypothesis the mixing chamber (MC) and the breath-by-breath (BbB) techniques measured the VO2 and VCO2 averages and their variabilities. Variances and power spectrum energies in the 0-0.5 Hertz band were measured to establish technique differences in steady and non-steady state. A hybrid calorimeter with both IC techniques studied a population of 15 volunteers that underwent the clino-orthostatic maneuver in order to produce the two physiological stages. The results showed that inter-individual VO2 and VCO2 variabilities measured as variances were negligible using the MC while variabilities measured as spectral energies using the BbB underwent 71 and 56% (p < 0.05), increase respectively. Additionally, the energy analysis showed an unexpected cyclic rhythm at 0.025 Hertz only during the orthostatic stage, which is new physiological information, not reported previusly. The VO2 and VCO2 inter-individual averages increased to 63 and 39% by the MC (p < 0.05) and 32 and 40% using the BbB (p < 0.1), respectively, without noticeable statistical differences among techniques. The conclusions are: (a) metabolic monitors should simultaneously include the MC and the BbB techniques to correctly interpret the steady or non-steady state variabilities effect in the REE estimation, (b) the MC is the appropriate technique to compute averages since it behaves as a low-pass filter that minimizes variances, (c) the BbB is the ideal technique to measure the variabilities since it can work as a high-pass filter to generate discrete time series able to accomplish spectral analysis, and (d) the new physiological information in the VO2 and VCO2 variabilities can help to understand why metabolic monitors with dissimilar IC techniques give different results in the REE estimation.
منابع مشابه
Measuring energy expenditure in the intensive care unit: a comparison of indirect calorimetry by E-sCOVX and Quark RMR with Deltatrac II in mechanically ventilated critically ill patients.
BACKGROUND Indirect calorimetry allows the determination of energy expenditure in critically ill patients by measuring oxygen consumption (VO2) and carbon dioxide production (VCO2). Recent studies have demonstrated variable performance of "breath-by-breath" instruments compared to mixing chamber technology. The aim of this study was to validate two modern devices (E-sCOVX and Quark RMR) against...
متن کاملAn Accurate Metabolic Simulator for Indirect Calorimetry System Validation
A metabolic simulator capable of simulation of respiratory oxygen consumption (VO2) and carbon dioxide production (VCO2) for validation of indirect calorimetry systems is described. The metabolic simulator adds/removes respiratory gases by way of mass flow controllers to/from a physiologically realistic lung simulator (Michigan Instruments Inc. Training/Test Lung). The metabolic simulator and M...
متن کاملModification of the thermogenic effect of acutely inhaled salbutamol by chronic inhalation in normal subjects.
BACKGROUND Acute inhalation of clinical doses of salbutamol in normal volunteers increases resting metabolic rate by up to 20% above control values. This study was designed to see if chronic treatment with salbutamol causes a sustained increase in metabolic rate and whether it modifies the acute thermogenic response to the drug. METHODS The effects of chronic inhaled salbutamol on resting oxy...
متن کاملClinical Study Hyperoxia Reversibly Alters Oxygen Consumption andMetabolism
Aim. Ventilation with pure oxygen (hyperoxic ventilation: HV) is thought to decrease whole body oxygen consumption (VO2). However, the validity and impact of this phenomenon remain ambiguous; until now, under hyperoxic conditions, VO2 has only been determined by the reverse Fick principle, a method with inherent methodological problems. The goal of this study was to determine changes of VO2, ca...
متن کاملA Cross-sectional Study of Resting Cardio-respiratory and Metabolic Changes in Pregnant Women
[Purpose] We examined cardiorespiratory and metabolic changes across the 1st (G1), 2nd (G2) and 3rd (G3) trimesters in pregnant women. [Subjects and Methods] Forty-two healthy, active, non-smoking, pregnant women participated in this study. They were divided into G1, G2 and G3 groups depending on their mean gestational ages at the time of testing which were 10.5 ±2.9, 19.2 ±3.4, and 33.3 ±2.4 w...
متن کامل